Instruction manual

PAGE - 10
Key
Parameters Function Range Pre.setting Description
HVP -20 Parameters List for DA-281 (MAC. 73)--version 1.0 N
Parameters
Code
Positioning mode selection.
OFF Needle up and down is adjusted by external synchronizer, and needle bar upper dead point is adjusted by
183.PUB
A Needle up is adjusted by 179.PUA, and needle down is adjusted by181.PDA.
B Needle up is adjusted by 179.PUA, needle down is adjusted by181.PDA
and needle bar upper dead point is adjusted by 183.PUB.
C When pedal control, needle up is adjusted by179.PUA, needle down is adjusted by184.PDB,185.PDC ;
if U switch operation in half stitch control; then, can stop the motor at 179.PUA,181.PDA】【184.PDB,
185.PDC. this function for handle stitch machine only.
Defined one signal for two positioning function. Note : Valid only when 176.VDN=off .
ONEnable. A single positioning signal synchronizer is used.
OFFDisable. A regular synchronizer is used.
Valid only when177. SIN=ON +176. VDN= OFF.
H: Input logic H active for needle up, and input logic L active for needle down.
L: Input logic H active for needle down, and input logic L active for needle up.
179 PUA Virtual up A position edge angle 0 - 359 degrees 338 176. VDN=MODE "A","B","C" valid (from index point).
180 PUW Virtual up A position ON angle 10 - 70 degrees 40 176. VDN=MODE "A","B","C" valid (pulse width).
181 PDA Virtual down A position edge angle 0 - 359 degrees 62 176. VDN=MODE "A","B","C" valid (from index point).
182 PDW Virtual down A position ON angle 10 - 70 degrees 40
176. VDN=MODE "A","B","C" valid (pulse width).
183 PUB Virtual up B position edge angle 0 - 359 degrees 338 176. VDN=MODE "B" , "Off" valid (needle upper dead point).
184 PDB Virtual down B position edge angle 0 - 359 degrees 90 176. VDN=MODE "C" valid only
185 PDC Virtual down C position edge angle 0 - 359 degrees 270 176. VDN=MODE "C" valid only
186 MS Walking foot lifting maximum speed 200 - 5000 spm 3500 Walking foot maximum speed limiter
187 WS Walking foot lifting minimum speed 200 - 4800 spm 2000 The speed of HP solenoid on
188 MIN
Minimum stroke value of potentiometer for
walking foot lifting .
0 - 255 --- Min. stroke adjusted by the potentiometer at machine head.
189 MAX
Maximum stroke value of potentiometer for
walking foot lifting .
0 - 255 --- Max. stroke adjusted by the potentiometer at machine head.
190 B2 DB2000 speed limiter 400 - 5000 spm 2000 B2 speed limiter setting
191 B3 DB3000 speed limiter 500 - 5000 spm 3000 B3 speed limiter setting
Positioning teaching mode selection.
ONMust be selected when 176. VDN = A,B,C.
OFFInvalid.
ON Enable. (Valid only with C300 operation panel selected double start back tacking, C60 invaild)
OFF Disable.
ON Enable. (Valid only with C300 operation panel selected double end back tacking, C60 invalid)
OFFDisable.
ON Normal stitch length.
OFF Long stitch length.
197 T6 Delayed timing prior to trimmer engaged 0 - 990 ms 0 Valid for079. LTM= T4/TK/TS/T7 and [158. O3] = KS4.
198 T7 Trimming time 0 - 990 ms 0 Valid for079. LTM= T1/T3/T4/TK/TS/T7 and [158. O3] = KS4.
Define the output function of O2.
NCLNeedle cooling output.
CK Needle down pulse width output .
Define the input function of IN4.
DB2Motor is running by 190. B2 speed.
SPV Speed limited by VHP input. Speed curve controlled by186. MS,187. WS】【188. MIN】【189. MAX .
NOPNo function.
S5
Motor is running by medium speed059. M.
WL Wiper output cancel switch.
Only valid when [063. FTP] set atMmode. For solenoid's switching power adjustment.
Note : Wrongly adjustment will cause the solenoid unable to lift or over-heating.
P
O
W
E
R
..
O
N
Stitch length selection after power on
DB2
NCL
ON
Positioning teaching mode ON/OFF
IN4
EB1
196 SLP
199 O2
195
192
200
193 RFC
PTE
VDN
Single End back-tacking function
O2=NCL/CK
output switchover
(HVP-20 Not support)
NCL/CK
ON/OFF
Single positioning signal synchronizer
176
SIN
Single Start back-tacking function
Define the UP positioning signal mode H/LNU
Backtacking output chopping duty-cycle
OFF
L
ON
40
ON
DB2/SPV/NOP/S5/WL
IN4=DB2/SPV/NOP/S5/WL
input sw switchover
(HVP-20 Not support)
178 H/L
ON/OFF
194 SB1
10 - 100 %
ONON/OFF
177 ON/OFF
BPositioning by index (reference) point OFF/A/B/C