Instruction manual
PAGE - 10
Key
Parameters Function Range Pre.setting Description
HVP -20 Parameters List for DA-281 (MAC. 73)--version 1.0 N
Parameters
Code
Positioning mode selection.
OFF: Needle up and down is adjusted by external synchronizer, and needle bar upper dead point is adjusted by
【183.PUB】
A: Needle up is adjusted by 【179.PUA】, and needle down is adjusted by【181.PDA】.
B: Needle up is adjusted by 【179.PUA】, needle down is adjusted by【181.PDA】
and needle bar upper dead point is adjusted by 【183.PUB】.
C: When pedal control, needle up is adjusted by【179.PUA】, needle down is adjusted by【184.PDB】,【185.PDC】 ;
if U switch operation in half stitch control; then, can stop the motor at 【179.PUA】,【181.PDA】【184.PDB】,
【185.PDC】. this function for handle stitch machine only.
Defined one signal for two positioning function. Note : Valid only when 【176.VDN】=off .
ON:Enable. A single positioning signal synchronizer is used.
OFF:Disable. A regular synchronizer is used.
Valid only when【177. SIN】=ON +【176. VDN】= OFF.
H: Input logic H active for needle up, and input logic L active for needle down.
L: Input logic H active for needle down, and input logic L active for needle up.
179 PUA Virtual up A position edge angle 0 - 359 degrees 338 【176. VDN】=MODE "A","B","C" valid (from index point).
180 PUW Virtual up A position ON angle 10 - 70 degrees 40 【176. VDN】=MODE "A","B","C" valid (pulse width).
181 PDA Virtual down A position edge angle 0 - 359 degrees 62 【176. VDN】=MODE "A","B","C" valid (from index point).
182 PDW Virtual down A position ON angle 10 - 70 degrees 40 【
176. VDN】=MODE "A","B","C" valid (pulse width).
183 PUB Virtual up B position edge angle 0 - 359 degrees 338 【176. VDN】=MODE "B" , "Off" valid (needle upper dead point).
184 PDB Virtual down B position edge angle 0 - 359 degrees 90 【176. VDN】=MODE "C" valid only
185 PDC Virtual down C position edge angle 0 - 359 degrees 270 【176. VDN】=MODE "C" valid only
186 MS Walking foot lifting maximum speed 200 - 5000 spm 3500 Walking foot maximum speed limiter
187 WS Walking foot lifting minimum speed 200 - 4800 spm 2000 The speed of HP solenoid on
188 MIN
Minimum stroke value of potentiometer for
walking foot lifting .
0 - 255 --- Min. stroke adjusted by the potentiometer at machine head.
189 MAX
Maximum stroke value of potentiometer for
walking foot lifting .
0 - 255 --- Max. stroke adjusted by the potentiometer at machine head.
190 B2 DB2000 speed limiter 400 - 5000 spm 2000 B2 speed limiter setting
191 B3 DB3000 speed limiter 500 - 5000 spm 3000 B3 speed limiter setting
Positioning teaching mode selection.
ON:Must be selected when 【176. VDN】 = A,B,C.
OFF:Invalid.
ON : Enable. (Valid only with C300 operation panel selected double start back tacking, C60 invaild)
OFF: Disable.
ON: Enable. (Valid only with C300 operation panel selected double end back tacking, C60 invalid)
OFF:Disable.
ON : Normal stitch length.
OFF: Long stitch length.
197 T6 Delayed timing prior to trimmer engaged 0 - 990 ms 0 Valid for【079. LTM】= T4/TK/TS/T7 and [158. O3] = KS4.
198 T7 Trimming time 0 - 990 ms 0 Valid for【079. LTM】= T1/T3/T4/TK/TS/T7 and [158. O3] = KS4.
Define the output function of O2.
NCL:Needle cooling output.
CK :Needle down pulse width output .
Define the input function of IN4.
DB2:Motor is running by 【190. B2】 speed.
SPV: Speed limited by VHP input. Speed curve controlled by【186. MS】,【187. WS】【188. MIN】【189. MAX】 .
NOP:No function.
S5:
Motor is running by medium speed【059. M】.
WL: Wiper output cancel switch.
Only valid when [063. FTP] set at「M」mode. For solenoid's switching power adjustment.
Note : Wrongly adjustment will cause the solenoid unable to lift or over-heating.
P
O
W
E
R
..
O
N
Stitch length selection after power on
DB2
NCL
ON
Positioning teaching mode ON/OFF
IN4
EB1
196 SLP
199 O2
195
192
200
193 RFC
PTE
VDN
Single End back-tacking function
O2=NCL/CK
output switchover
(HVP-20 Not support)
NCL/CK
ON/OFF
Single positioning signal synchronizer
176
SIN
Single Start back-tacking function
Define the UP positioning signal mode H/LNU
Backtacking output chopping duty-cycle
OFF
L
ON
40
ON
DB2/SPV/NOP/S5/WL
IN4=DB2/SPV/NOP/S5/WL
input sw switchover
(HVP-20 Not support)
178 H/L
ON/OFF
194 SB1
10 - 100 %
ONON/OFF
177 ON/OFF
BPositioning by index (reference) point OFF/A/B/C
+