Instruction manual
PAGE - 8
Key
Parameters Function Range Pre.setting Description
HVP -20 Parameters List for DA-281 (MAC. 73)--version 1.0 N
Parameters
Code
Define the input function of INE.
S7:An input signal for reverse sewing .
IO1:No function.
IO2:An input signal for reverse one stitch when motor stop and reverse sewing .
NOTE:The【010. ACD】=off and【011. RVM】=B must be set.
CW:Reverse run signal.
IO3:An input signal for Inching one stitch only when motor stop and reverse sewing .
NOTE:The【010. ACD】=off and【011. RVM】=B must be set.
U:Needle up function of 【125. USM 】.
BTL:Back-tacking suppression / recall switch for SBT/ EBT only.
BTC:Back-tacking suppression + O5 BTL Lamp On / cancel for SBT/ EBT only..
ST1:Inching one stitch only.
Define the input function of INF.
HP:An input signal for high lift of walking foot.
F:An input signal for knee switch.
Define the input function of INI.
CRS:An input signal for counter reset .Note : Valid only when 【042. CUD】=U,D,US,DS,UT,DT,UTS,DTS .
FAW:A signal for bobbin thread detector.
Define the input function of INK.
HP:An input signal for high lift of walking foot.
F:An input signal for knee switch.
CRR:Should be set when 【225.CER 】 = ON .
Define the output function of OA.
TM:Trimmer output.
KS1:Tape cutter output.
Define the output function of OB.
WP:Wiper output.
ML:Tension release output.
FK:Thread nipper output. Related parameter : [234.FAR] , [235.FKL].
KS1:No function.
NCL:Needle cooling output.
Define the output function of OD.
ML:Tension release output.
KS1:No function.
KS2:No function.
KS3:No function.
KS4:Must be selected when 【204. BL】 = ON or【205. BAF】= 1, 2.
NCL:Needle cooling output.
Define the output function of O1.
OT1: Output by flip-flop control ,according to each input specifications while inputs IO1 are ON.
KS1:No function.
PUL:Puller output.
CSL:Must be selected when 【225. CER】 = ON .
CK :Needle down pulse width output . Related parameter :【206. CK1 】【207. CK2 】
KS2 :Should be set when 【205. BAF 】=1, 2.
UC:Output is turned ON if at needle up position when the sewing machine is stopped.
PO1 :Needle down pulse width output .
PO2 :Needle up pulse width output .
P12 :Needle down , needle up pulse width output .
TM:Trimmer output.
P
O
W
E
R
..
O
N
INI
INI=CRS/FAW
input sw switchover
(HVP-20 Not support)
157
O1=OT1/KS1/PUL/CSL/CK/KS2/UC/
PO1/PO2/P12/TM
output switchover
(HVP-20 Not support)
OA TM
HP
F
CRS
OT1
OB
156
155
154
152
151
O1
OA=TM/KS1
output switchover
OD
ML/KS1/KS2/KS3/
KS4/NCL
OT1/KS1/PUL/CSL/
CK/KS2/UC/
PO1/PO2/P12/TM
OB=WP/ML/FK/KS1/NCL
output switchover
OD=ML/KS1/KS2/KS3/KS4/NCL
output switchover
WP/ML/FK/KS1/NCL
153
150
INK
INK=HP/F/CRR
input sw switchover
(HVP-20 Not support)
INF
INF=HP/F
input sw switchover
HP/F
ML
FK
TM/KS1
F/HP/CRR
FAW/CRS
INE
INE=S7/IO1/IO2/CW/IO3/U/BTL/BTC/ST1
input sw switchover
S7
S7/IO1/IO2/CW/IO3
U/BTL/BTC/ST1
+
S