Parameters Function Range Pre.setting Description
HVP -20 Parameters List for DA-281 (MAC. 73)--version 1.0 N
Parameters
Code
123 FASET Factory default reset Factory setting reset
Program mode selection.
NOP:No function
LOAD:Down load the program from operation panel .
SAVE:Save the program to operation panel.
COPY:Save the Host working area parameter value to operation panel , working area . (invalid with C-300 operation
IU:Current sensor initial value. (invalid with C-300 operation box)
IV:Current sensor initial value. (invalid with C-300 operation box)
Function for the needle up switch. Connection :【145. IN2】=U or【221.INJ】=U and C300,C60,F10 operation panel
needle up switch key. C-200 can use F multi-function key as needle up switch. (see C-200 user manual)
A:Stitch changeover + inching
B:Stitch changeover only
C:Up needle only .
D:Up needle and presser foot .
E:Inching one stitch only.
F:Inching one stitch backward only.
G:Backward running for【133. CHS】setting stitches.
H:Stitch changeover + Tension on + Sewing suppression + O5 BTL Lamp blinks .
ON:Always enable.
OFF:Enable only at intermediate stop .
127 MAV Maximum voltage hold ----- Maximum voltage display only.
128 MIV Minimum voltage hold ----- Minimum voltage display only.
129 PV Current voltage display ----- Display the current voltage.
130 OVD Over voltage setting 310 - 315 315V Over voltage setting
131 LVD Low voltage setting 70 - 160 70V Low voltage setting
Save the user's parameter setting into memory blocks for later use. Setting procedure:
1.Press [S] key + POWER ON LCD display 【123. FASET】
2.Press [P] key 9 times LCD display 【132. UPG 】
3.Press [S] key LCD display 【UPG. 0 】
4.Press [D] key to select a block number from【UPG. 0】 ~ 【UPG. 4 】.
5.Press [A] key to save the program.
Note : To recall the program, go to the memory block in 【UPG. 0】 ~ 【UPG. 4 】, use [C] key to call it back
and then press [S] key to confirm and save.
133 CHS
Function and stitches setting for Angle-Stitch
device ( Pegasus W582)
1 - 99 stitches 5
Valid only when【047. MAC】 =『 10 』( For W582 angle stitch ) and【 011. RVM】= 『 B 』.
When half heeling the pedal, the needle goes up , pressing down the pedal, this function works.
The『CHS』speed is set by【004. N 】.
Full heeling back : Same as interlock stitch machine function output.
ON: The A.B.C.D keys will be locked and defined to specific functions as follow :
A key : Cancel foot lifting after at half- heeling pedal .
B key : Cancel trimmer function at full heeling pedal.
C key : Cancel wiper function at full heeling pedal.
D key : Start constant stitch setting
OFF:Unlocked. C-200 can turn off both start / end back-tacking key to enter the special functions (see C-200 user
135 TOT Auto-running full time setting 1 - 168 Hrs 1 Auto-running full time setting. when 【138. UTD】 = ON valid.
(1-250 )x0.1S Auto-running on cycle time setting. when【138. UTD】 = ON valid.
1-250 ms when [160.O5] is setting TF the value is output delay time (x10ms)
(1-250 )x0.1S Auto-running off cycle time setting. when 【138. UTD】 = ON valid.
1-250 ms when [160.O5] is setting TF the value is output delay time (x10ms)
ON:Enable.
OFF:Disable.
139 PSL Speed curve adjustments 1 - 100% 85 The larger the value the faster to up speed
Setting the parameter 【102. SE 】from C-300 operation box .
ON:Enable.
OFF:Disable.
P
O
W
E
R
..
O
N
136
137
ON/OFF
20
20
OFF
OFFON/OFFOSE
OFF
Function for the needle up switch
Program down load from operation box / save
to operation box
NOP/LOAD/SAVE/
COPY/IU/IV
User program saving
NOP
SBT/EBT Key Lock selection
0 - 4
ONMode selection for【125. USM 】 ON/OFF
0
134
124
USM
TM2
PG
USA
UPG
TM1
Outside setting the 【102. SE 】 parameter
KLK
UTD Auto-running test selection
Auto-running off cycle time setting
Auto-running on cycle time setting
126
138
140
ON/OFF
A/B/C/D/E/F/G/H B
132
125
+
S