Instruction manual

PAGE - 4
Key
Parameters Function Range Pre.setting Description
HVP -20 Parameters List for DA-281 (MAC. 73)--version 1.0 N
Parameters
Code
Foot lifter output signal converted.
ON : The foot lifter goes up during sewing.
OFF: Function invalid.
Trimming device protection for Cover-Stitch machine.
NCNormal close. When signal at open , motor immediately stops and rotation symbol will stop.
NONormal open. When signal at close , motor immediately stops and rotation symbol will stop.
NOPCancel safety switch function (No Trimming device protection)
With TCL trigger signal input, the next trimming will be cancelled as full heeling the pedal.
ONValid.
OFFInvalid.
Canceling the interlock timer for quick restarting. For machine without trimmer device only.
ONValid.
OFFInvalid.
Motor running mode at trimming sequence selection.
LKFor general Lock-Stitch machines .Trimming from needle down to up.
RKFor Chain-Stitch machine easy pull out cycle. Needle stops with a reverse angle set by 116.DRU.
KAFor general Cover-Stitch machines with under trimmer only.
KBFor special Cover-Stitch machines with upper trimmer .
KCValid only when 079. LTM=TK and 081. TS】>0, otherwise function same as LK mode.
Reference the timing chart
T1At down position delayed 081. TS angles on, at up position delayed 083. T2 time off.
T2At down position delayed081. TS angles on, extended084. TE angles off.
T3At down position delayed 081. TS angles on, extended 083. T2time off.
T4At down position delayed 082. T1 time on, extended083. T2 time off.
TKAt up position delayed082. T1 time on, extended
083. T2 time off.
TSAt down position always on, at up position delayed 082. T1 time on, extended083. T2 time.
T7At down position delayed081. TSangles on, at up position off, and delayed 082. T1time on,
extended083. T2time off.
Reference the timing chart
L1At down position delayed085. LS angles on, at up position delayed 087. L2time off.
L2At down position delayed085. LSangles on, extended088. LEangles off.
L3At down position delayed 085. LS angles on, extended 087. L2time off.
L4At down position delayed 086. L1 time on, extended 087. L2 time off.
LKAt up position delayed086. L1 time on, extended087. L2 time off.
LSAt down position always on, at up position delayed 086. L1 time on, extended 087. L2 time off.
L7At down position delayed
085. LS angles on, at up position off, and delayed 086. L1 time on,
extended087. L2 time off.
81 TS Delayed angles prior to trimmer engaged 0 - 360 degrees 0 Valid for079. LTM= T1/T2/T3/T7 .
82 T1 Delayed timing prior to trimmer engaged 0 - 990 ms 0 Valid for079. LTM= T4/TK/TS/T7.
83 T2 Trimming time 0 - 990 ms 40 Valid for079. LTM= T1/T3/T4/TK/TS/T7.
84 TE Setting angles of trimming 0 - 360 degrees 0 Valid for079. LTM = T2 .
85 LS Delayed angles prior to tension release engaged 0 - 360 degrees 0 Valid for080. LLM = L1/L2/L3/L7 .
86 L1
Delayed
timing
prior
to
tension
release
engaged
0 - 990 ms 0 Valid for080. LLM= L4/LK/LS/L7.
87 L2 Timing of tension release 0 - 1500 ms 0 Valid for080. LLM = L1/L3/L4/LK/LS/L7.
88 LE Setting angles of tension release 0 - 360 degrees 0 Valid for080. LLM= L2 .
89 D1
Dela
y
ed timin
g
for u
pp
er trimmer at down-sto
p
0 - 990 m
s
0
90 D2 Setting timing of upper trimming at down-stop 0 - 2500 ms 0
91 D3 Timing recall of upper trimming at down-stop 0 - 990 ms 0
92 W1 Delayed timing prior to wiper engaged 0 - 980 ms 0 Time setting between needle up to wiper active.
93 W2 Setting timing of wiping 0 - 9990 ms 100 Wiper ON timer setting.
94 WF Delayed timing prior to foot lifter engaged 0 - 990 ms 0 Timer setting between wiper OFF to presses foot ON.
Condense-Stitch function by027. CT timer for needle up & motor stop.
ONEnable. Note :021. EBT =ON,022. EBC=8,023.EBD=3 and 024.EBN=2 and 027. CT=100
must be adjusted.
OFFDisable.
96 CON Setting stitches of Condense-Stitch sewing 0 - 99 stitches 8 Valid only when the [095. CSF] = ON.
Tape cutter on timer 0 - 2500 ms Tape cutter on timer setting x10 = 100 ms.
Bobbin counter alarm preaction value. 0 - 250 stitches When 042.CUD= US,DS the value is bobbin counter alarm preaction value.
stitches
p
rior to sto
p
be
y
ond Condense-Stitch
0 - 250 stitches 0
V
alid onl
y
when the
[
095. CSF
]
= ON.
P
O
W
E
R
..
O
N
Mode selection for tension-release sequence.
(For ML output signal)
Motor running mode at trimming sequenceTRM
LLM80
Only valid when078. TRMset at KB mode.
Signal output from the wiper MW.
See the KB timing chart.
OFF
75 SFM Safety switch protection mode NC/NO/NOP NC
Converter for foot lifter signal output74 FRV ON/OFF
OFF
77 ILC
Cancel of interlock timing after full heeling
pedal
ON/OFF OFF
76 TCL Thread trimmer cancel ON/OFF
L1/L2/L3/L4/LK/LS/L7
KB
79 LTM
Mode selection for trimming sequence.
( For TM output signal )
T1/T2/T3/T4/TK/TS/T7 TS
LK/RK/KA/KB/KC
LS
78
10
97 TK3
OFF95 CSF Condense-Stitch function selection ON/OFF
P