Instruction manual
PAGE - 3
Key
Parameters Function Range Pre.setting Description
HVP -20 Parameters List for DA-281 (MAC. 73)--version 1.0 N
Parameters
Code
47 MAC Machine Code 0 - 101 73 Machine code switchover
Positioning Mode selection.
ON:One position UP only.
OFF:Two positions Up / DOWN.
49 SPD Machine's pulley dimension. 1 - 250 mm 75 Setting machine pulley size when【051. PL】 = ON valid.
50 MPD Motor's pulley dimension. 1 - 250 mm 75 Setting motor pulley size when 【051. PL】 = ON valid.
Selecting the mode of setting pulley ratio.
ON: Manually setting the pulley sizes by 【049, SPD】,【050, MPD】 .
OFF:Automatically setting the pulley sizes by the CPU.
52 BT Braking time of motor 50 - 500 ms 200 Braking time of motor
Slow start at the first cycle of power ON function selection.
ON:Enable and speed is set by 【007. S 】.
OFF:Disable.
Motor stops with brake function.
ON:Enable.
OFF:Disable.
Valid only when needle stops at up position.
ON:Enable. When the needle stops at up position, the first stitching will be done with a reverse angle which is set by
the 【056.SRA】.
OFF:Disable.
Exception: If【147. INA】= BCR, an external switch may be used as a selection of ON / OFF to this function.
56 SRA Setting the angles of 【055. SRM】 1 - 360 degrees 60 Valid only when【055. SRM】= ON.
ON:Enable.
OFF:Disable.
58 TR8 Setting the angles of 【057. TRU】 1 - 360 degrees 14 Valid only when【057.TRU 】= ON .
59 M Middle speed L speed - 8000 spm 800 Setting the middle speed.
60 L Low speed 50 - 500 spm 250 Low speed adjustments
61 T Thread trimming speed 50 - 500 spm 180 Thread trimming speed adjustments
For machines have HP function only.
【 ALT 】mode : Presser foot lifting stroke changed by each time of the HP switch pushed on.
【 MON 】mode : Presser foot lifting stroke must be remained by the HP switch kept on.
M : Magnetic type.
A : Air type.
Note : When set at A type, 【064. FO 】and【065. FC 】setting will be invalid. It will be full on.
64 FO Full-On time setting for foot lifting solenoid 0 - 990 ms 250 Only valid when【063. FTP】set at『 M 』mode. For solenoid pulling torque adjustment.
65 FC Duty cycle time setting for foot lifting solenoid 10 - 90% 40
Only valid when【063. FTP】set at「M」mode. For solenoid's switching power adjustment.
Note : Wrongly adjustment will cause the solenoid unable to lift or over-heating.
66 FD Running-Delay time setting 0 - 990 ms 80 If foot lifter is installed, set 100 ms min. to ensure the presser foot will come down first.
Selection of solenoid protection.
ON: The foot lifting solenoid activated time will be controlled by 【068. FP】.
OFF : The foot lifting solenoid will be always active unless heeling back the pedal.
68 FP
Workin
g
time limit for foot lifter solenoid.
(
0 - 9990
)
x 0.01
s
3000
Settin
g
the liftin
g
solenoid activated time. Valid onl
y
when the 【067. FPM】 = ON.
69 HD Sensitivity adjustment for half-heeling pedal 0 - 990 80
Use this setting as foot lifter delay time at half heeling the pedal. If foot lifter is installed, set 100 ms min.
1.If timing set to short, it will cause foot lifter started once before trimming at full heeling the pedal.
2.If timing set to long, it will cause foot lifter started too slow or laggard at half heeling the pedal.
ON : No foot lifting at half-heeling. (but full-heeling can operate foot lifter )
OFF : Operate foot lifting at half-heeling.
Note : When【134.KLK】= ON for interlock-stitch machine, this function can be controlled by A key on the control box
panel.
ON : No foot lifting at heeling pedal.
OFF : Has foot lifting at heeling pedal.
ON : No function at heeling pedal. ( foot lifter and need up function are also invalid)
OFF : Trimmer is functioned at heeling pedal.
When the pedal is returned to neutral position, trimming works automatically.
O N : Enable. Only valid when【072.FHC】= OFF
OFF:Disable.
P
O
W
E
R
..
O
N
57
55 SRM Motor start running with a reverse angle
67
72
63
62
TRU Motor stops with a reverse angle after trimming ON/OFF
HPM
FTP
FPM
Mode for foot lifting stroke change at special
compound feed machine.
FL
73
FHC
NTC
71
OFF
51 PL Pulley's ratio setting mode selection ON/OFF ON
48 N12
Positioning Mode selection
(ON=UP ONLY, OFF=UP/DOWN)
ON/OFF
ON
54 BK Motor braked at normal stop ON/OFF OFF
53 POL Slow start at the first cycle of power ON ON/OFF
ALT/MON
OFF
OFF
MON
ON/OFF
MM/AType selection for foot lifting solenoid
ONON/OFFProtection for foot lifter solenoid.
ONON/OFFCancel foot lifting at half-heeling pedalHHC
OFFON/OFFTrimming works at neutral pedal
ON/OFF OFF
OFFCancel trimming at full-heeling pedal ON/OFF
Cancel foot lifting at full- heeling pedal
70
+
P