(4). Value setting for A、B、C、D key in the【Parameter Value】:
IN TERMS OF SPEED 1000 spm 100 spm 10 spm 1 spm
IN TERMS OF ANGLE --------
100 ° 10 ° 1 °
IN TERMS OF TIMING 1000 ms 100 ms
10 ms 10 ms
IN TERMS OF FUNCTION FUNCTION SWAP
※ Other than the function selection, each press of the key will start change the value from 0 to 9 .
SCALE
TERMS
KEY
A B C D
Note : After value change, press S key to save the value, otherwise the new value will be lost
when turning power off.