9
5. C-200 Operation Panel Key Functions
(1). Panel key functions
Function key :
1 Parameter enter / Increment Enter parameter mode / parameter NO. increment key.
2
Parameter value / Save / Enter
multi-function
Enter value area / Save key / Enter multi-function
3 F multi-function Definable multi-function key
4 Start back-tacking
Stitches for A、B section, 15 stitches max. /
Parameter NO. increment
5 End back-tacking
Stitches for C、D section, 15 stitches max. /
Parameter NO. decrement
6 LED display
Parameters / functions / A、B、C、D area value display.
7 Constant-stitch sewing
13 sections max. (P1~PD section), 250 stitches max. for
each section.
8 Bar-tacking
15 stitches max. for A、B、C section, 15 turns max. (D=0 for
unlimited turns)
9 Power ON LED Power ON LED / Warning LED
10
A、B、C、D area value adjust key
= increment / = decrement
11 External LED light switch
For external LED light, its ON or OFF state can be
memorized by the operation panel.
12 Auto Automatic function for constant-stitch sewing.
13 Trimming Trimming function ON or OFF
14 External LED light socket The socket for external DC 12V LED light.
(2). Other functions by panel key combination :
Function Key combination Description
Operation panel
reset function
Reset the panel function setting(not include
the parameter setting)
Parameter reset
function
Reset the parameter setting to default value.
Motor rotating icon
selection
Cancel the motor rotating icon on the LED
panel
Parameter mode A
Refer to how to enter parameter mode A
Parameter mode B
Refer to how to enter parameter mode B
.
11
9
Front
12
13
6
10
7
8
3
4
5
2
1
9
14
Back
1
2
12V 0V
External LED wiring layout
LED: DC 12V
100 ma (max)
Power ON
+
C
+
A
Power ON
+
B
+
A
Power ON
+
D
+
B
P
Power ON
+
P
Hold for 2 sec.
+
Note : After install the external LED light, make sure that the LED
and its cable are firmly secured to avoid the LED or its cable
fall into the running motor or machine.