Instruction manual
PAGE 9
software version : D2.8(FOR HVP70-4-ED only)
100 ohm 220 ohm 680 ohm 1000 ohm2200 ohm
DescriptionRangeParameters Function
Parameters
Code
Preset For
HVP-70 Sewing Machine Controller Parameters Setting List (for durkopp) E2
KEY
MAKE
R
Positionin
g
mode selection.
OFF : Needle up and down is ad
j
usted b
y
external s
y
nchronizer, and needle bar upper dead point is
A
: Needle u
p
is ad
j
usted b
y
[
179. PUA
]
, and needle down is ad
j
usted b
y
[
181. PDA
]
.
B : Needle up is adjusted by [179. PUA] , needle down is adjusted by [181. PDA]
and needle bar u
pp
er dead
p
oint is ad
j
usted b
y
[
183. PUB
]
.
C : When pedal control, needle up is adjusted by [179.PUA] , needle down is adjusted by [184. PDB] ,
[185. PDC] ; if U switch operation in half stitch control; then, can stop the motor at [179. PUA] , [181.
PDA
]
[
184. PDB
]
,
[
185. PDC
]
. this function for handle stitch machine onl
y
.
Defined one si
g
nal for two
p
ositionin
g
function. Note : Valid onl
y
when
[
176. VDN
]
=off .
ON : Enable. A sin
g
le positionin
g
si
g
nal s
y
nchronizer is used.
V
alid onl
y
when
[
177. SIN
]
=ON +
[
176. VDN
]
= OFF.
V
alid onl
y
when
[
177. SIN
]
=ON +
[
176. VDN
]
= OFF.
H : Input lo
g
ic H active for needle up, and input lo
g
ic L active for needle down.
L : Input lo
g
ic H active for needle down, and input lo
g
ic L active for needle up.
179 PUA
V
irtual up A position ed
g
e an
g
le
0 - 359 degrees 266 266 315 326 266
[
176. VDN
]
=MODE "A","B","C" valid
(
from index point
).
180 PUW
V
irtual up A position ON an
g
le
10 - 70 degrees 40 40 40 40 40
[
176. VDN
]
=MODE "A","B","C" valid
(
pulse width
).
181 PDA
V
irtual down A position ed
g
e an
g
le
0 - 359 degrees 0 0 115 21 0
[
176. VDN
]
=MODE "A","B","C" valid
(
from index point
).
182 PDW
V
irtual down A position ON an
g
le
10 - 70 degrees 40 40 40 40 40
[
176. VDN
]
=MODE "A","B","C" valid
(
pulse width
).
183 PUB
V
irtual up B position ed
g
e an
g
le
0 - 359 degrees 266 238 295 266 266
[
176. VDN
]
=MODE "B" , "Off" valid
(
needle upper dead point
)
.
184 PDB
V
irtual down B position ed
g
e an
g
le
0 - 359 degrees 90 90 90 90 90
[
176. VDN
]
=MODE "C" valid onl
y
185 PDC
V
irtual down C position ed
g
e an
g
le
0 - 359 degrees 270 270 270 270 270
[
176. VDN
]
=MODE "C" valid onl
y
186 MS
Walkin
g
foot liftin
g
maximum speed
400 - 5000 spm 3500 900 1700 3500 3500
Walkin
g
foot maximum speed limite
r
187 WS
Walkin
g
foot liftin
g
minimum speed
400 - 4800 spm 2000 400 800 2000 2000
The speed of HP solenoid on
188 MIN
Minimum stroke value of potentiometer for
walking foot lifting .
----- ---- ---- ----
52 (see :
No.236)
---- Min. stroke adjusted by the potentiometer at machine head.
189 MAX
Maximum stroke value of potentiometer for
walking foot lifting .
----- ---- ---- ----
255 (See :
No.236)
---- Max. stroke adjusted by the potentiometer at machine head.
190 B2
DB2000 speed limiter
400 - 5000 spm 2000 400 800 2000 2000 B2 speed limiter setting
191 B3
DB3000 speed limiter
500 - 5000 spm 3000 500 1700 3000 3000 B3 speed limiter setting
Positionin
g
teachin
g
mode selection.
ON : Must be selected when
[
176. VDN
]
= A,B,C.
OFF : Invalid.
ON : Enable.
(
Valid onl
y
with C300 operation panel , select double start back tackin
g)
OFF : Disable.
ON : Enable.
(
Valid onl
y
with C300 operation panel , select double end back tackin
g)
OFF : Disable.
The slow start operation mode is selected. This is valid when the panel
[
SL
]
ke
y
is ON in the normal
T:Slow start operation will begin when the power is turned ON or when the first toe down after thread
trimming, or the first external run signal (S0,S1) is turned ON.
A:Slow start operation will begin when the pedal is toed down or when the external run signal (S0,S1)
is turned ON.
BF function selection.
ON : Enable. Connected parameter :
[
148. INC
]
OFF : Disable.
197 LFO
Full-on time for Tension release solenoid.
0 - 990 ms 100 100 100 100 100
For tension solenoid full-on time ad
j
ustment.
198 LFC
Duty cycle of holding power for Tension
release solenoid. Related parameter : [155.
OB
]
,
[
156. OD
]
=ML .
10 - 100% 50 50 50 50 50 Valid when [155. OB] ,[156. OD] = ML , For solenoid switching power adjustment.
When
[
239. KLC
]
=ON. Settin
g
the number of stitches for the walkin
g
foot o
p
eration.
0 : Function disable.
1 ~ 255 : Stitches settin
g
. Valid onl
y
when
[
062. HPM
]
=ALT.
[
239. KLC
]
=ON.
TT195 SLM Slow start operation mode T/A T T T
B176 VDN Positioning by index (reference) point OFF/A/B/C
OFF OFF OFF177 SIN Single positioning signal synchronizer ON/OFF
Define the UP positioning signal mode H/L H/L L L
ON192 PTE Positioning teaching mode ON/OFF
ON193 SB1 Single Start back-tacking function ON/OFF
ON194 EB1 Single End back-tacking function ON/OFF
OFF196 BF BF function ON/OFF
0199 FHP
Setting the number of stitches for HP
function.
0 - 255 stitches
P
O
W
E
R
..
ON
178 NU
000
OFFOFFOFF OFF
0
ONONON
ONONON
ON
ONONON
BBB
OFF
LL
B
OFF
L
ON
ON
+