Instruction manual

PAGE 9
software version : D2.8(FOR HVP70-4-ED only)
100 ohm 220 ohm 680 ohm 1000 ohm2200 ohm
DescriptionRangeParameters Function
Parameters
Code
Preset For
HVP-70 Sewing Machine Controller Parameters Setting List (for durkopp) E2
KEY
MAKE
R
Positionin
g
mode selection.
OFF : Needle up and down is ad
j
usted b
y
external s
y
nchronizer, and needle bar upper dead point is
A
: Needle u
p
is ad
j
usted b
y
[
179. PUA
]
, and needle down is ad
j
usted b
y
[
181. PDA
]
.
B : Needle up is adjusted by [179. PUA] , needle down is adjusted by [181. PDA]
and needle bar u
pp
er dead
p
oint is ad
j
usted b
y
[
183. PUB
]
.
C : When pedal control, needle up is adjusted by [179.PUA] , needle down is adjusted by [184. PDB] ,
[185. PDC] ; if U switch operation in half stitch control; then, can stop the motor at [179. PUA] , [181.
PDA
]
[
184. PDB
]
,
[
185. PDC
]
. this function for handle stitch machine onl
y
.
Defined one si
g
nal for two
p
ositionin
g
function. Note : Valid onl
y
when
[
176. VDN
]
=off .
ON : Enable. A sin
g
le positionin
g
si
g
nal s
y
nchronizer is used.
V
alid onl
y
when
[
177. SIN
]
=ON +
[
176. VDN
]
= OFF.
V
alid onl
y
when
[
177. SIN
]
=ON +
[
176. VDN
]
= OFF.
H : Input lo
g
ic H active for needle up, and input lo
g
ic L active for needle down.
L : Input lo
g
ic H active for needle down, and input lo
g
ic L active for needle up.
179 PUA
V
irtual up A position ed
g
e an
g
le
0 - 359 degrees 266 266 315 326 266
[
176. VDN
]
=MODE "A","B","C" valid
(
from index point
).
180 PUW
V
irtual up A position ON an
g
le
10 - 70 degrees 40 40 40 40 40
[
176. VDN
]
=MODE "A","B","C" valid
(
pulse width
).
181 PDA
V
irtual down A position ed
g
e an
g
le
0 - 359 degrees 0 0 115 21 0
[
176. VDN
]
=MODE "A","B","C" valid
(
from index point
).
182 PDW
V
irtual down A position ON an
g
le
10 - 70 degrees 40 40 40 40 40
[
176. VDN
]
=MODE "A","B","C" valid
(
pulse width
).
183 PUB
V
irtual up B position ed
g
e an
g
le
0 - 359 degrees 266 238 295 266 266
[
176. VDN
]
=MODE "B" , "Off" valid
(
needle upper dead point
)
.
184 PDB
V
irtual down B position ed
g
e an
g
le
0 - 359 degrees 90 90 90 90 90
[
176. VDN
]
=MODE "C" valid onl
y
185 PDC
V
irtual down C position ed
g
e an
g
le
0 - 359 degrees 270 270 270 270 270
[
176. VDN
]
=MODE "C" valid onl
y
186 MS
Walkin
g
foot liftin
g
maximum speed
400 - 5000 spm 3500 900 1700 3500 3500
Walkin
g
foot maximum speed limite
r
187 WS
Walkin
g
foot liftin
g
minimum speed
400 - 4800 spm 2000 400 800 2000 2000
The speed of HP solenoid on
188 MIN
Minimum stroke value of potentiometer for
walking foot lifting .
----- ---- ---- ----
52 (see :
No.236)
---- Min. stroke adjusted by the potentiometer at machine head.
189 MAX
Maximum stroke value of potentiometer for
walking foot lifting .
----- ---- ---- ----
255 (See :
No.236)
---- Max. stroke adjusted by the potentiometer at machine head.
190 B2
DB2000 speed limiter
400 - 5000 spm 2000 400 800 2000 2000 B2 speed limiter setting
191 B3
DB3000 speed limiter
500 - 5000 spm 3000 500 1700 3000 3000 B3 speed limiter setting
Positionin
g
teachin
g
mode selection.
ON : Must be selected when
[
176. VDN
]
= A,B,C.
OFF : Invalid.
ON : Enable.
(
Valid onl
y
with C300 operation panel , select double start back tackin
g)
OFF : Disable.
ON : Enable.
(
Valid onl
y
with C300 operation panel , select double end back tackin
g)
OFF : Disable.
The slow start operation mode is selected. This is valid when the panel
[
SL
]
ke
y
is ON in the normal
TSlow start operation will begin when the power is turned ON or when the first toe down after thread
trimming, or the first external run signal (S0,S1) is turned ON.
ASlow start operation will begin when the pedal is toed down or when the external run signal (S0,S1)
is turned ON.
BF function selection.
ON : Enable. Connected parameter :
[
148. INC
]
OFF : Disable.
197 LFO
Full-on time for Tension release solenoid.
0 - 990 ms 100 100 100 100 100
For tension solenoid full-on time ad
j
ustment.
198 LFC
Duty cycle of holding power for Tension
release solenoid. Related parameter : [155.
OB
]
,
[
156. OD
]
=ML .
10 - 100 50 50 50 50 50 Valid when [155. OB] ,[156. OD] = ML , For solenoid switching power adjustment.
When
[
239. KLC
]
=ON. Settin
g
the number of stitches for the walkin
g
foot o
p
eration.
0 : Function disable.
1 ~ 255 : Stitches settin
g
. Valid onl
y
when
[
062. HPM
]
=ALT.
[
239. KLC
]
=ON.
TT195 SLM Slow start operation mode T/A T T T
B176 VDN Positioning by index (reference) point OFF/A/B/C
OFF OFF OFF177 SIN Single positioning signal synchronizer ON/OFF
Define the UP positioning signal mode H/L H/L L L
ON192 PTE Positioning teaching mode ON/OFF
ON193 SB1 Single Start back-tacking function ON/OFF
ON194 EB1 Single End back-tacking function ON/OFF
OFF196 BF BF function ON/OFF
0199 FHP
Setting the number of stitches for HP
function.
0 - 255 stitches
P
O
W
E
R
..
ON
178 NU
000
OFFOFFOFF OFF
0
ONONON
ONONON
ON
ONONON
BBB
OFF
LL
B
OFF
L
ON
ON