Instruction manual

PAGE 8
software version : D2.8(FOR HVP70-4-ED only)
100 ohm 220 ohm 680 ohm 1000 ohm2200 ohm
DescriptionRangeParameters Function
Parameters
Code
Preset For
HVP-70 Sewing Machine Controller Parameters Setting List (for durkopp) E2
KEY
MAKE
R
Define the input function of INK.
HP : A switch input si
g
nal for hi
g
h lift of walkin
g
foot.
F : A switch input si
g
nal for knee switch.
CRR : Should be set when
[
225. CER
]
= ON .
Define the output function of OA.
TM : Trimmer output.
KS1 : Tape cutter output.
Define the output function of OB.
WP : Wiper output.
ML : Tension release output.
KFA : Short trimmin
g
output
.
Define the output function of OD.
ML : Tension release output.
KS1 : No function.
KS2 : Must be selected when
[
194. A16
]
= ON.
KS3 : No function.
KS4 : Default settin
g
. Must be selected when
[
196. BF
]
or
[
204. BL
]
= ON, or
[
205. BAF
]
= 1, 2 .
NCL : Needle coolin
g
output.
Define the output function of O1.
OT1 : Output b
y
flip-flop control ,accordin
g
to each input specifications while inputs IO1 are ON.
KS1 : Must be selected when
[
193. AC2
]
or
[
194. A16
]
or
[
197. WDA
]
= ON
.
PUL : Puller output.
CSL : Must be selected when
[
225. CER
]
= ON .
TM : Trimmer output.
Define the output function of O3.
HP : Output for hi
g
h lift for walkin
g
foot.
KS1 : Must be selected when
[
205. BAF
]
= 1, 2 .
KS2 : Must be selected when
[
196. BF
]
= ON .
CSR : Must be selected when
[
225. CER
]
= ON .
Define the output function of O4.
OT4 : Reserve output.
BUZ : Buzzer output is turned On when the [042. CUD] =US,DS,UTS,DTS and the count becomes end.
RESET : When the counter reset b
y
p
ushin
g
the "A" ke
y
at
p
anel of controller or b
y
[
152. INI
]
=CRS
D11 : If (D/3) is defined for FSPR switch, then (D/11) as FSPR LED output, if (D/3) is defined for VRU
switch, then
(
D/11
)
as VRU LE
D
Define the output function of O5.
OT5 : Must be selected when
[
197. WDA
]
= ON or
[
205. BAF
]
= 1, 2.
HPL : HP_LED output.
Define the output function of O6.
STL : STK_LED output.
OT6 : Output is turned ON for chain stitch bottom/lamp, when the pedal full heelin
g
back or sewin
g
Define the output function of O7.
BTL : BTL_LED output.
UC : Output is turned ON if at needle up position when the sewin
g
machine is stoped.
163 BD
SRM return operation stable timer
70 - 990 70 70 70 70 70
Stable timer for motor return operation.
164 MXI
Maximum current limite
r
5 - 22
A
10 19 19 19 10
Maximum current limiter settin
g
. Note : To avoid dama
g
e, ad
j
ustment should be done b
y
en
g
ineer onl
y
.
165 WKT
Weak brakin
g
torque scale
1 - 5 2 2 2 2 2
Weak brakin
g
torque scale settin
g
.
166 ACT Acceleration time 60 - 990 ms 140 140 140 140 140
The time for accelerating machine to high speed from the pedal toed down or when the external run
si
g
nal
(
S1
)
is turned ON.
167 DCT Deceleration time 60 - 990 ms 160 160 160 160 160
The time for the decelerating machine to stop from the pedal returned to neutral
or when the external run si
g
nal
(
S1
)
is turned OFF .
168 HKP
Motor's holdin
g
torque
g
ain ad
j
.
5 - 400 35 20 40 20 35
To reduce noise, the motor holdin
g
torque can be lowered down.
169 LKP
Low speed
g
ain
5 - 400 50 25 50 25 50
Low speed
g
ain LKP ad
j
ustment.
170 KP
Gain kp
10 - 150 40 20 40 20 40 Gain kp adjustments
171 KI
Gain ki
100 - 3000 1800 1800 1800 1800 1800 Gain ki adjustments
172 KS
Gain ks
1 - 40 18 18 18 18 18 Gain ks adjustments
173 QSK
Quick stop counter
30 - 999 100 100 100 100 100
Note : Don't ad
j
ust.
174 QSP
Quick stop speed
50 - 500 100 100 100 100 100
Note : Don't ad
j
ust.
Heav
y
dut
y
function settin
g
ON : Enable.
OFF : Disable.
P
O
W
E
R
..
ON
HP153 INK Definition INK=HP/F/CRR (A/7 or B/1) HP/F/CRR
TM154 OA Definition OA=TM/KS1 (A/37) TM/KS1 TM
155 OB Definition OB=WP/ML/KFA (A/27)
TM
ML ML
WP/ML/KFA WP WP WP
MLML
WPWP
OT1/KS1/PUL/C
SL/TM
Definition O1=OT1/KS1/PUL/CSL/TM (A/30)
156 OD
Definition OD=ML/KS1/KS2/KS3/KS4/NCL
(A/36 or B/5 or C/5)
ML/KS1/KS2/
KS3/KS4/NCL
O1157 OT1OT1 OT1 OT1
HP158 O3 Definition O3=HP/KS1/KS2/CSR (A/32) HP/KS1/KS2/CSR
D11159 O4 Definition O4=OT4/BUZ/D11 (D/11) OT4/BUZ/D11
HPL160 O5 Definition O5=OT5/HPL (A/31) OT5/HPL
STL161 O6 Definition O6=STL/OT6 (A/29 or D/10) STL/OT6
BTL162 O7 Definition O7=BTL/UC (A/24) BTL/UC
OFF175 HV Heavy duty ON/OFF
TM TM
OFFOFFOFF
BTLBTLBTL BTL
OFF
STLSTLSTL
HPLHPLHPL HPL
STL
D11D11D11
HPHPHP
HPHPHP HP
ML
OT1
HP
D11