Instruction manual
PAGE 1
software version : D2.8(FOR HVP70-4-ED only)
100 ohm 220 ohm 680 ohm 1000 ohm2200 ohm
USER
1
H
Maximum sewin
g
speed
50 - 9999 spm 4800 900 1700 3500 6600 Maximum speed adjustments
2 PSL
Speed curve ad
j
ustments
1 - 100% 85 45 55 85 85 The larger the value the faster to up speed
3 CNR Counter ratio selection 1 - 100 1 1 1 1 1
Setting the multiple to the value of [042. CUD]
Connection :
[
042. CUD
]
,
[
159. O4
]
,
[
097. TK3
]
4N
Start back-tackin
g
speed
50 - 8000 spm 1700 400 800 1200 1700 Start back-tacking speed adjustments
5V
End back-tackin
g
speed
50 - 8000 spm 1700 400 800 1200 1700 End back-tacking speed adjustments
6B
Bar-Tackin
g
Speed
50 - 8000 spm 1700 400 800 1200 1700 Bar-Tacking Speed adjustments
7S
Soft start speed
50 - 2000 spm 800 250 400 400 800 Soft start speed adjustments
8 SLS
Stitch numbers for soft start
0 - 99 stitches 2 2 2 2 2 Soft start stitches setting
9A
Automatic constant-stitch sewin
g
speed
50 - 8000 spm 4800 900 1700 3500 6600
V
alid only at the auto pattern sewing or one shot signal (SH) active
Only at the last seam of pattern sewing
ON : Valid.
OFF : Invalid.
J = JUK mode , B = BROTHER mode.
J : Active when motor stop or running.
B : Active only when motor running.
Start back-tackin
g
mode selection
A
: One shot sewin
g
M : Pedal control and motor can stop at middle wa
y
.
SU : One shot sewin
g
but motor stops at needle up b
y
[
027. CT
]
timer at end of each seam.
SD : One shot sewin
g
but motor stops at needle down b
y
[
027. CT
]
timer at end of each seam.
A
t the end of Start back-tackin
g
mode selection.
CON : At the end of Start back-tacking ,machine continues sewing if pedal pressed or START signal on
(
standin
g
o
p
eration
)
STP : At the end of Start Back-Tacking, machine stops and must re-start by pedal command.
TRM : Makin
g
the trimmin
g
c
y
cle once the Start Back-Tackin
g
finished.
(
Mini Bar tackin
g
)
V
alid onl
y
when the operation panel disconnected.
ON : Perform
OFF : Not perform
15 SBA
Settin
g
stitches A of Start back-tackin
g
33333
16 SBB
Settin
g
stitches B of Start back-tackin
g
33333
17 SBN
Settin
g
turns of Start back-tackin
g
0 - 4 times 2 2 2 2 2 Setting the seam times of Start back-tacking , [014. SBT] = ON valid
18 BT1
Stitch balance for Start back-tackin
g
1
3 4 4 4 3 BT1=0 : Invalid,1-8 : Increase stitches of reverse seam; 9-F : Increase stitches of forward seam
19 BT2
Stitch balance for Start back-tackin
g
2
7 3 3 3 7 BT2=0 : Invalid,1-8 : Increase stitches of forward seam; 9-F : Increase stitches of reverse seam
End back-taking mode selection.
A : One shot sewing.
SU : One shot sewing but machine stops up position by [027. CT] timer at the end of each seam.
SD : One shot sewing but machine stops down position by [027. CT] timer at the end of each seam.
V
alid onl
y
when the operation panel disconnected.
ON : Perform
OFF : Not perform
22 EBC
Settin
g
stitches C of End back-tackin
g
33333
23 EBD
Settin
g
stitches D of End back-tackin
g
33333
24 EBN
Settin
g
turns of End back-tackin
g
0 - 4 times 2 2 2 2 2 Setting the seam times of End back-tacking , [021. EBT] = ON valid
25 BT3
Stitch balance for End back-tackin
g
3
7 2 2 2 7 BT3=0 : Invalid, 1-8 : Increase stitches of reverse seam; 9-F : Increase stitches of forward seam
26 BT4
Stitch balance for End back-tackin
g
4
1 1 1 1 1 BT4=0 : Invalid, 1-8 : Increase stitches of forward seam; 9-F : Increase stitches of reverse seam
[012. SMS] , [020. SME] , [031. SMB] = SU,SD setting valid.
Conner stop timer, valid onl
y
at
[
012. SMS
]
,
[
020. SME
]
,
[
031. SMB
]
settin
g
SU/SD
.
A
dditional 15 stitches are added to the Start and End back-tackin
g
stitches function selection.
ON : valid.
OFF : Invalid.
29 SB9
0-99 stitches plus on Start/End back-
0 - 99 stitches 0 0 0 0 0
A
dditional setting stitches are added to the Start and End back-tacking stitches.
DescriptionRangeParameters Function
Parameters
Code
Preset For
ON10 ACD Automatic sewing End back-tacking ON/OFF
A
J11 RVM Back-tacking mode selection J/B
12 SMS Mode selection for Start back-tacking A/M/SU/SD
CON13 TYS
Mode selection at the end of Start back-
tacking
CON/STP/TRM
ON14 SBT Start back-tacking selection ON/OFF
0 - 15 stitches Start back-tacking stitches setting , [014. SBT] = ON valid
0 - F
20 SME Mode selection for End back-tacking A/SU/SD A A A
ON ON ON ONON21 EBT End back-tacking selection ON/OFF
0 - 15 stitches End back-tacking stitches setting , [021. EBT] = ON valid
0 - F
27 CT
Setting time interruption at each section
End of Back-Tacking.
0 - 990 ms 50 270 150
OFF OFF OFF OFF28 SB5 15 stitches plus on Start/End back-tacking ON/OFF
HVP-70 Sewing Machine Controller Parameters Setting List (for durkopp) E2
KEY
P
O
W
E
R
..
ON
ONONON
50
A
ON
A
CONCONCON
AAAA
CON
JJJ
ONONON ON
J
100
OFF