Instruction manual
- 15 -
b. Press and hold keys, then turn ON the power.
LED will display【 RESE T】and blink twice.
A B
P S
STOP
P S
A B C D
STOP
P S
A B C D
8. How to use【Recovery】to go back at factory default :
Press S key to save
P S
Lockstitch
c. After blinking, the recovery starts and
then goes back to【 Normal mode 】
a. Turn OFF power.
o
r
OFF ON
(Three phase )
(Single phase)
P
d. Must press Key to save the function.
LED will display【SAVE. OK】and blink twice .
S
STOP
P S
A B C D
.
STOP
P S
A B C D
.
STOP
P S
A B C D
.
e. goes back to【 Normal mode 】
Lockstitch
Remark:
1. Above operation only suitable for the software version D2..3 and above
(see Parameter【208. VER】for software version)
2. If the software version is before the version D2.3, then at step d.
LED will
not display【SAVE. OK】and will not blink twice. But need press the
key three times to return to the【Normal Mode】(see Note).
S
Note : Operation instructions for the software before version D2.3
After saving need to press the key 3 times to return to the【 Normal mode 】area.
Press 1st time,
LED will show Bar-tacking.
Press 2nd time, LED will show Constant stitch
Press 3
rd
time, will return to the【Normal mode 】area.
S
【 b 4 4 】
‧
‧
【 P 1 15 】
‧
‧