Instruction manual
- 13 -
(3). How to set the Parameter Value :
Note 1: Confirm the parameter code you want to adjust. (See the parameter table for detail)
Note 2: Follow below steps to adjust parameter value.
(4). Value setting for 、 、 、 key in the【Parameter Value】:
A B C D
IN TERMS OF SPEED 1000 spm 100 spm 10 spm 1 spm
IN TERMS OF ANGLE --------
100 ° 10 ° 1 °
IN TERMS OF TRIMMING 1000 ms 100 ms
10 ms 10 ms
IN TERMS OF FUNCTION FUNCTION SWAP FUNCTION SWAP
※ 1. Other than the function selection, each press of the key will start change the value from
0 to 9 。
2. When【
134. KLK 】set『 ON 』, it acts as special function『 ON / OFF 』key. See the chapter 5.5 (Page.11) for detail。
SCALE
TERMS
KEY
A B C D
Note : After value change, press key to save the value, otherwise they will lose after
turning power off.
S
Step 1: Enter one of the【 Parameter Mode A to E 】.
Step 2: Press or key to select the target parameter number.
Step 3: Press key to enter the parameter value.
S
Step 4: Press key to adjust the value.
A
B C D
Step 5: Press key to save the value and return to【Normal Mode】automatically.
S
Caution:
1. Must operate in the【Normal mode】, an operating area of sewing can start motor.
2.【Parameter mode】, an setting area of parameter, disable from running motor.