Instruction manual

- 13 -
(3). How to set the Parameter Value :
Note 1 Confirm the parameter code you want to adjust. (See the parameter table for detail)
Note 2 Follow below steps to adjust parameter value.
(4). Value setting for key in theParameter Value:
A B C D
IN TERMS OF SPEED 1000 spm 100 spm 10 spm 1 spm
IN TERMS OF ANGLE --------
100 ° 10 ° 1 °
IN TERMS OF TRIMMING 1000 ms 100 ms
10 ms 10 ms
IN TERMS OF FUNCTION FUNCTION SWAP FUNCTION SWAP
1. Other than the function selection, each press of the key will start change the value from
0 to 9
2. When
134. KLK set ON , it acts as special function ON / OFF key. See the chapter 5.5 (Page.11) for detail
SCALE
TERMS
KEY
A B C D
Note After value change, press key to save the value, otherwise they will lose after
turning power off.
S
Step 1 Enter one of the Parameter Mode A to E .
Step 2 Press or key to select the target parameter number.
Step 3 Press key to enter the parameter value.
S
Step 4 Press key to adjust the value.
A
B C D
Step 5 Press key to save the value and return toNormal Modeautomatically.
S
Caution
1. Must operate in theNormal mode, an operating area of sewing can start motor.
2.Parameter mode, an setting area of parameter, disable from running motor.