M01 Global parameters 2110-5
Pos. global parameters 2110-5 Value Unit
01
Till CLAMP SIDEWAYS FWD
0.0 sec
02
TILL CLAMP DOWN
0.2 sec
03
TILL VACUUM OFF
0.0 sec
04
THREAD LENGTH spool full
000 m
05
TILL CLAMP INSERTING
0.1 sec
06
SEWING END ->CL.SIDEW.
0.0 sec
07
TIME AFTER CLA MP OPEN
0.1 sec
10
TILL FOLDING CL. CLOSED
0.5 sec
11
TILL FOLDER LIFT UP
0.3 sec
12
TILL FOLDER SWINGS LEFT
0.3 sec
13
IMPULS FOLDER DOWN
0.04 sec
14
CL.OPEN TILL FOLDER UP
0.20 sec
17
TILL TENSION OPEN
0.00 sec
18
DURATION OF TENS. OPEN
0.5 sec
19
TILL THREAD CLAMP FORW
0.1 sec
20
DUR.THREAD CLAMP FORW
0.5 sec
21
TILL STACKER TRANSPORT
0,3 sec
22
DUR.SLIDING TABLE OPEN
0.8 sec
23
LIFT.TABLE MOD 00/01-99
00
24
DUR.LIFTING TABLE SINKS
0.99 sec
25 TILL FABRIC CLAMP FORW. 0.0 sec
26 TILL SCISSORS CLOSED 0.0 sec
27 DURATION SCISSORS CUTS 0.0 sec
28 TILL FABRIC CLAMP OPEN 0.0 sec
29 TILL SWING RETAINER DW N 0.0 sec
30 TILL RETAINER SWINGS 0.0 sec
31 DUR. OF PULLING RETAINER 0.0 sec
32 BLOW OUT THE PART 0.0 sec
33 TILL THRUST FOR REMOVAL 0.0 sec
35
THREAD CATCH. "UP" POS
200 INC
36
SWITCH ON POS.OF TRIMM
000 INC
37
TRIMMING SPEED
180 Upm
38
DURATION OF TRIMMING
0.35 sec
39 THREAD CATCH.TURNS BACK 00 INC