Operating instructions

Short Seam Automat 2110-5 / 2111-5 Workinging Instructions
- D 82 -
Beisler Automated Sewing Equipment
D.3
Programming
D.3.10 Level 2 special parameters / Lists
Parameter setting for level 2 submenus
The following section describes the special parameters that
are set in lists. When a submenu is requested, only tho-
se positions of the parameter list are displayed that refer
to the machine function. All other positions of the entire
parameter list can be browsed.
Move to a line in the list:
Press # or $ key.
Special parameter menu:
& 2?3A

F1 Back to start level
F3 Select start modes, list
F4 Set upper part parameters, list
F5 Set stitch lengths and bar tacks, list
F6 Parameters for clamp transport, list
Selecting start modes
2
Press key
Change parameters:
Press % key.
Insert new value using numeric keypad or
Press 0 or / key.
Confirm input:
Press % key.
Settable values
Start mode
The selected start mode determines how the machine
operation is started and executed. Four modes are availa-
ble:
Mode 00,
Mode 01,
Mode 02,
Mode 03.
The individual settings for machine operation are described
in Section B.3.11, Machine operation.
Setting upper part parameters
This list is used for setting all parameters for functions of
the sewing head.
The minimum and maximum values of input are limited
by the program control unit. Values that are not within the
limits will not be accepted but reduced to the correspon-
ding minimum or maximum value.
?
Press key
The parameter list is shown on the display.
NOTE - Sewing speed!
Possible settings for the sewing speed refer to the following
sewing ranges:
Sewing speed 1 to the start distance,
sewing speed 2 to the center distance,
sewing speed 3 to the end of the seam.
The speed is set in increments of 100 rpm.