Operating instructions

Short Seam Automat 2110-5 / 2111-5 Working Instructions
- C 46 -
Beisler Automated Sewing Equipment
C.5
Maintenance
C.5.5 Machine set-up
Photocell light sensitivity setting:
The photocell
1
at the sewing head controls the begin-
ning and the end of the sewing process.
The sensitivity of the photocell must be set in accordance
with the sewing material used.
This function must be adjusted correctly (see section
D.3.2).
1. Fig. 18: Make sure that the light beam
2
of the pho-
tocell is not interrupted.
2. Unlock the keypad:
Keep the two buttons
5
and
6
(+ / -) depressed for
approx 5 seconds.
The green LED
8
illuminates momentarily to indicate
the unlocked state. The keypad remains unlocked for
4 minutes (red LED
7
flashes), then the light guide
controller is locked automatically.
3. Set sensitivity using buttons
5
and
6
:
Press + to increase sensitivity.
Press - to reduce sensitivity.
4. Interrupt light beam
2
with the sewing material to be
used
3
; if the yellow LED
9
fails to go off, reduce
sensitivity.
NOTE - Red LED!
The red LED
6
must not illuminate in any switching state.
If the red LED illuminates, the light amplifier is in a criti-
cal switching state. In this case, increase the photocell sen-
sitivity until the red LED goes off, then set the sensitivity
in accordance with the sewing material used as descri-
bed above.
Fig. 18
Fig. 18
1
3
7
5
4
8
9
1
2
6