Operating instructions
Error- Description Possible cause Troubleshooting
code
7701 Error Protocol Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
8151
8156
-
8159
Error IDMA - Failure
- Control faulty
- Switch the sewing machine off
and on again
- Replace control
8152
-
8154
8251
8255
Error IDMA / Booting
ADSP / Booting
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
8252
8257
8258
/
8253
8256
8254
Booting ADSP /
Booting XILINX /
Booting
Failure
- Switch the sewing machine off
and on again
8351
8700
8702
8800
-
8806
8890
8891
Error Testpins / Key
simulation / Signals /
Event processing /
Memory-Wrapper /
List of functions
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
9100
-
9105
9200
9201
9900
9902
9903
9905
Error seam pattern
administration / seam
pattern program /
seam pattern release /
Equipment / Key
processing / Memory
Output Message
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
If the error 9100 appears
repeatedly, go through the
initialization menu and reset the
seam pattern programs and
sequences (compare to page 62).
9906 Error monitoring
switch clamping foot
- Switch faulty
- Cable faulty
- Distance switch-lug
too big
- Check the switch
- Check the cable
- Check the clearance
After troubleshooting set the
machine parameters to the factory
settings, so that the switch can be
recognized again (compare to page
62).
Should an error occurs, the corresponding component can be checked
over the menu service/multi-test for its correct function (compare to
page 49). The service menu can be reached by switching to the
”Technician mode" or by pressing the key F when switching on the
machine (enter the code number “25483").
86