Operating instructions

Error- Description Possible cause Troubleshooting
code
5804 Free seam patterns:
Wrong checksum
- NV-SRAM faulty
- Failure
- Check via Multitest,
check the control
- Switch the sewing machine off
and on again
Data will be reset to factory setting.
5808 Error free seam
contour
Cannot determine the
stitch number
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
5809 Free seam patterns:
Max. number of seam
pattern parts
Max. number of seam
pattern parts (intermediate
cut) exceeded
Delete some intermediate cut in the
free seam patterns
5810 Free seam patterns:
Min. number of stitches
per seam pattern part
Cannot keep the min.
number of stitches per
seam pattern part
Move some intermediate cut in the
free seam patterns
5900 Error sequences –
Invalid sequence
number
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
6151
-
6154
Error input/output Internal error
Switch the sewing machine off
and on again
6351
-
6354
Error I
2
C Control faulty
- Check control
- Software update
- Contact the DA-Service staff
6551
-
6554
6651
-
6653
6751
-
6761
6952
Error
Machine head
position /
AD-Converter /
Processor error / Step
motor driver
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
7451
7453
7454
Communication Test
Interface
Internal error
Switch the sewing machine off
and on again
7452
7455
Communication Test
Interface
- Transmission failure
- Cable Test interface
faulty
- Internal error
- Switch off the source of
interference
- Check cable
- Switch the sewing machine off
and on again
7551
-
7555
7558
7559
Communication
Terminal interface
Internal error - Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
7556
7557
Communication
Terminal interface
- Transmission failure
- Cable Terminal interface
faulty
- Switch off the source of
interference
- Check cable
7700 Protocol: Max number
of repetition
- Transmission failure
- Cable Test interface
faulty
- Switch off the source of
interference
- Check cable
85