Error- Description Possible cause Troubleshooting
code
2201 Step motor Y-Axis
Timeout Referencing
- Cable to reference
switch faulty
- Reference switch faulty
- Step motor faulty
- Mechanical part
rough-running
- Check cable
- Check reference switch
Check step motor
- Check the mechanical part
2252 Step motor Y-Axis
overcurrent
- Step motor Y-Axis
faulty
- Control faulty
- Check step motor Y-Axis
- Check control
2253 Step motor Y-Axis
overvoltage
Mains voltage too high Check the mains voltage
2256 Step motor Y-Axis
overheat
- Step motor Y-Axis
rough-running
- Step motor Y-Axis faulty
- Control faulty
- Eliminate rough-running
- Check Step motor Y-Axis
- Check control
2262 Step motor Y-Axis
IDMA Autoincrement
Failure Switch the sewing machine off
and on again
2911
2914
Step motor error Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
3100 Machine control
voltage
Temporary mains voltage
drop
Fuse F403 faulty
Check the mains voltage
Replace fuse F403
3101 Machine power
voltage
Temporary mains voltage
drop
Fuse F402 faulty
Check the mains voltage
Replace fuse F402
3102 Machine voltage
intermediate circuit
sewing motor
Temporary mains voltage
drop
Fuses F400/F404 faulty
(ext.)*
Check the mains voltage
Replace fuses F400/F404 (ext.)
3103 Machine voltage
intermediate circuit
step motors
Temporary mains voltage
drop
Fuse F401 faulty
Check the mains voltage
Replace fuse F401
3107 Machine temperature - Vent holes closed
- Ventilation grid dirty
- Check the vent holes
- Clean the ventilation grid
3215 Machine hook thread
counter zero
The counter for the hook
thread counter is zero :
the bobbin is empty
Confirm the message and replace
the bobbin.
* Those fuses could also be faulty when the control unit does not react and/or powering up does nothing!