Operating instructions
Output test
With this test function the function of the output elements is checked.
–
Start the test function with the key “OK”.
–
Select desired output element with the keys “ñ”or“ò”.
–
Switch desired output element on and off with the key “OK”.
output test
output
–
Press function key “ESC” for leaving the test function.
Caution: Danger of injury !
Do not reach into the running machine during the function test of the
output elements.
Output element Function
Y 1 Laser marking light 1, if the option is activated
Y 2 Laser marking light 2, if the option is activated
Y 3 Laser marking light 3, if the option is activated
Y 4 Separated clamping foot 1, if the option is activated
Y 5 Separated clamping foot 2, if the option is activated
Y 6 Depending on the activated option and the output configuration
Y 7 Depending on the activated option and the output configuration
Y 8 Depending on the activated option and the output configuration
The recent configuration of the outputs is indicated in the submenu
“Output configuration” of the menu equipment.
52