Operating instructions
Submenu Times
The submenu times is only displayed, when the corresponding options
are activated or the seam patterntoring switch of the clamping foot is
not connected.
Delay between pedal level 1 (lowering the clamping foot) and
sewing start (t1)
Time only relevant with quick start via pedal or hand switch (optional).
The above menu item will only be displayed, if the monitoring switch of
the clamping foot is not connected.
Input: 50 ...300 ms
Preset value: 250 ms
Turn-on delay for the thread wiper magnet (t2)
This menu item will only be displayed if the option “electric thread
wiper” is activated in the menu “equipment”.
Input: 30 ...100 ms
Preset value: 40 ms
Delay thread wiper magnet off - clamping foot magnet on (t3)
The delay between the switching off of the thread wiper magnet and
the switching on of the clamping foot magnet.
This menu item will only be displayed if the option “electric thread
wiper” is activated in the menu “equipment”.
Input: 0 ...300 ms
Preset value: 50 ms
Delay between clamping foot magnet on —reference run (t4)
The delay between the switching on of the clamping foot magnet and
the referencing of the step motors.
Input: 0 ...300 ms
Preset value: 100 ms
1
43