Operating instructions

Clamping foot Max. Dim. X x Y Inner frame Description
number tack size [mm] rectangular
(X x Y) [mm] Inner frame
1 19.0 x 3.5 20.0 x 4.5 yes Straight bartack
2 20.0 x 4.1 21.0 x 5.1 yes Straight bartack
3 27.0 x 5.0 27,0 x 5,0 yes Straight bartack, large
4 10.0 x 4.5 10,0 x 4,5 yes Straight bartack, small
5 5.6 x 23.0 5,6 x 23,0 yes Longitudinal bartack
6 19.0 x 12.0 19,0 x 12,0 yes Small field clamping foot
7 44.0 x 24.0 44,0 x 24,0 yes Large field clamping foot
8 9.5 x 4.5 9,5 x 4,5 yes Contraction clamp
9 16.0 x 16.0 16,0 x 16,0 no Circle
10 12.0 x 14.0 12,0 x 14,0 no D-clamping foot, simple
11 24.6 x 12.6 24,6 x 12,6 no Double D-clamping foot, lateral
12 12.6 x 21.0 12,6 x 21,0 no Double D-clamping foot, longitud.
13 34.8 x 12.2 34,8 x 12,2 no Double Tri-clamping foot, lateral
14 16.0 x 2.6 17,0 x 3,6 yes “Belt loop”
16 8,6 x 13,6 24,0 x 14,6 no Double D-clamping foot, lateral
Length
Input of a freely selectable sewing field.
Input only possible in case “free clamp dimension”
had been selected. Otherwise the length / width of
the selected clamp is indicated (cannot be modified).
Input: 0.5 … 20.0
Width
Input of a freely selectable sewing field.
Input only possible in case “free clamp dimension”
had been selected. Otherwise the length / width of
the selected clamp is indicated (cannot be modified).
Input: 0.5 … 40.0
Configuration
Via this submenu the optional units can be activated.
Danger of Breakage!
When making the clamps for open dimensions a safety margin
must be considered.
40