Instruction manual

7 Pneumatic connection
ATTENTION !
The pneumatic units will only operate properly at a supply
pressureof8to10bar.
The sewing machine’s operating pressure is 6bar.
Pneumatic connection package
Under the order number 0797 003031 a pneumatic connection
package for stands with compressed a ir maintenance unit is available.
It includes the following components:
Connecting hose, 5 m long Ø = 9 mm
Hose nozzles and hose clamps
Coupling socket and connector plug
Maintenance unit with manometer and pressure regulator
Connecting the compressed air maintenance unit
Fasten the compressed a ir maintenance unit 2 to the stand strut
with angle, screws and flap.
Connect the compressed air maintenance unit to the compressed
air supply with connecting hose 4 = 9 mm) and hose coupling
R1/4".
Setting the operating pressure
The operating pressure is 6bar.
It can be read off at manometer 3.
For adjusting the operating pressure raise and tur n handle 1.
Increase the pressure = Tur n twist handle 1 clockwise
Reduce the pressure = Turn twist handle 1 counter-clockwise
15
GB
2
4
6
8
10
1
2
3
4