Operating instructions

6.4.5.1 Seam Parameters
6.4.5.1.1 Editing the fullness regulation
Tap the symbol for upper or lower feed.
The following display screen appears.
With cylinder With stepper motor
1 = Display of the current seam
2 = Display of t he fullness in the home position (stepper motor)
3 = Fullness regulation is enabled
4=Switchingonthesegments
5 = Switching on the segments for quick adjustment on the
main display screen (stepper motor)
6 = Fullness in the 5 segments towards which the sewing motor
moves
7 = Number of stitches in the segments 1 - 5
8=Saving
With cylinder With stepper motor
Segment 1 Segment 2 Segment 3 Segment 1 Segment 2Segment 3 Segment 4 Segment 5
Stitches Stitches Stitches Basic seam Stitches Stitches Stitches Stitches Stitches Basic seam
Note
The parameters of the home positions 2 are located in the “Global
Parameters” with the numbers “40” and “42”.
36
123
8
5
6
7
13
8
4
7