Operating instructions
Adjusting the holding stamp
Via this parameter the holding stamp is adjusted.
Parameter 15: Time when the stamp lowers.
Setting range: 0 …20
Parameter 16: Time how long the warp separator remains switched
on.
Setting range: 0 …100
Parameter 17: Switch the stacker on or off
Setting range: 0 / 1
Parameter 47: Time of stacker movement
Setting range: 0 …2000
Parameter 57: Time how long the holding stamp is down
Setting range: 0 …2000
Altering the machine parameters
Parameter 30: Set the main speed
Setting range: 0 …8500
Parameter 31: Switch manual sewing on or off
Setting range: 0 / 1
Parameter 32: Number of stitches how long the table blowing
remains switched on
Setting range: 0 …400 stitches
Parameter 34: Number of stitches until the contour guide
lowers
Input: 0 …400 stitches
Parameter 44: Number of stitches until the contour guide
lowers
Input: 0 …200
Parameter 60: Softstart speed
Setting range:
500 ...5000
Parameter 61: Switch the softstart on or off
Setting range: 0 / 1
Parameter 76: Switch the start via light barrier on or off
Setting range: 0 / 1
Parameter 77: Switch the autostart on or off
Setting range: 0 / 1
Parameter 78: Number of stitches when the autostart starts
Setting range: 0 ...400 stitches
Parameter 98: Switch the lining clamp on or off
Setting range: 0 / 1
25
1