Operating instructions

6.4.3 Input - Output test
Via the input - output test the different input and output elements can
be checked.
Input test
Press key “P”.
Press key “8”.
Actuate the corresponding input.
Example:
Cover the light barrier.
Press key “Program stop”.
The program is quitted.
Input elements
Switch Designation
01 Light barrier 01
05 Switch “Program stop”
Output test
Press key “P”.
Press key “8”.
Press key “Plus”.
Select the output element to be tested with the keys “Plus” or
Minus”.
Switch the output on or off with the key “F2”.
Press key “Program stop”.
The program is quitted.
Output elements
Switch Designation
Y01 Sewing foot up / down
Y02 Thread tension lift open / closed
Y03 Contour guide up / down
Y04 Stacker off / on
Y05 Holding stamp up / down
Y06 Auxiliary roller up / down
Y12 Warp separator off / on
Y13 Table blowing off / on
Y14 Dirt suction off / on
20