Operating instructions
6.4.3 Input - Output test
Via the input - output test the different input and output elements can
be checked.
Input test
–
Press key “P”.
–
Press key “8”.
–
Actuate the corresponding input.
Example:
Cover the light barrier.
–
Press key “Program stop”.
The program is quitted.
Input elements
Switch Designation
01 Light barrier 01
05 Switch “Program stop”
Output test
–
Press key “P”.
–
Press key “8”.
–
Press key “Plus”.
–
Select the output element to be tested with the keys “Plus” or
“Minus”.
–
Switch the output on or off with the key “F2”.
–
Press key “Program stop”.
The program is quitted.
Output elements
Switch Designation
Y01 Sewing foot up / down
Y02 Thread tension lift open / closed
Y03 Contour guide up / down
Y04 Stacker off / on
Y05 Holding stamp up / down
Y06 Auxiliary roller up / down
Y12 Warp separator off / on
Y13 Table blowing off / on
Y14 Dirt suction off / on
20