Operating instructions

6.4.2 Altering the global parameters
Parameter 45: Number of stitches until the table blowing is
switched on
Input: 0 …200
Parameter 46: Duration of the stacker impulse
Input: 0 ..2000
Parameter 47: Time of stacker movement
Input: 0 …2000
Parameter 48: Speed limitation
Input: max. 7000
Parameter 49: Speed at warp separation
Input: 0 …5000
Parameter 50: Number of stitches until the thread tension
is opened (seam end)
Input: 0....50
Parameter 56: Seam programming on/ off
On = Determine the seam sequences in the current
program
Off = Create the next free program with seams
Input: 0 and 1
Parameter 58: Display of the software version
Parameter 59: Number of stitches how long the seam chain is
sucked (seam beginning)
Input: 0 ...150
19
1