Instruction manual
- 25 -
1. To change the maximum speed (Ex. to change to 3500 rotations) ............ Function setting [H.3500]
(1)
Call out the program mode [P] function [H].
(This can be called with mode call or direct number call. Refer to pages 14 to 16.
(Direct call number = "0000") )
(2)
Press the [+] and [-] keys ([A], [B], [C], [D]), and set to "3500".
(3)
Entering the normal mode
For mode call: [Ļ] + [Ĺ]
For direct number call: Set with and then press .
Description
A. The setting range of the maximum speed is 0 to 8999 rotations.
B. By pressing each of the [A], [B], [C] and [D] keys, the setting value will change between 0 and 9. (However, the [A] key is only
between 1 and 8.) To lower the value, press the [A], [B], [C], [D] keys while holding down the [Shift] key.
C. The factory setting is [4000 rotations].
D. Low speed, thread trimming speed, start tacking speed, end tacking speed, medium speed and slow start speed can be set in
the same manner.
Memo
The LED.D dot will flicker after the setting is changed.
This indicates that the factory setting value (default
value) has been changed.
(This explanation regarding the flickering dot is omitted in the following explanations.)
2. To set the standing work type .......Function setting [AT.ON]
(1)
Call out the program mode [P] function [AT].
(This can be called with mode call or direct number call. Refer to pages 14 to 16.
(Direct call number = "0033"))
(2)
*Press the [D] key and set to "ON" for the setting value.
(3)
Entering the normal mode
For mode call: [Ļ] + [Ĺ]
For direct number call: Set with and then press .
Description
A. This is used for high speed operation during standing operations.
When setting it to turning ON, it operates at the speed with the rate which has been set with the [C] and the [D] key in normal
mode regardless of the pedal stepping quantity.
B. This setting is first priority to the key switch [AUTO] of control switch panel (XC-G500 type).
C. The setting value will alternate between [OF] and [ON] with each press of the [D] key in step (2). (The factory setting is [OF])
Note : The switches for standing operation are connected as shown on 14-2-(2) page 43. Be sure to set the function [PDS] to ON
in the program mode [C] as shown on page 43.
11 Example of setting the program mode