Instruction manual

Table Of Contents
32
12. CONNECTING THE DOWNSTREAM UNIT
Paper conveyed to the downstream unit when paper feed error occurs (no paper, mis feed, double-feed,
etc.) will be ejected without binding. In this case, operations of the DFC-12/10 can be stopped or contin-
ued according to preference. At shipment, Error paper ejection is set to Stoppage.
1
Press the key and display
"On-line setting".
Press the key and display the
screen for selecting "Booklet
maker", "Trimmer", and "Error paper
ejection".
Press the key to display the "Er-
ror paper ejection" screen, and next press
the
key to display the after clearing
screen.
2
3
Press the key to display the
screen for selecting whether to con-
tinue or stop operations after ejec-
tion.
Press the key to display the
screen where the operation to be set is
blinking.
4
Press the key and save the op-
eration selected at step 3.
To redo the setting, press the key an-
other time to return to step 3.
5
Press the key to return to the
standby screen.
Press the key until the standby screen
is displayed.
Setting "After clearing paper feed error"
Note Even though Continuation is selected,
operations stop when feeding errors oc-
cur twice successively. In case of high
speed, another set may be fed after those
erroneous sets. This set will be, however,
ejected without binding.
When On-line setting is set to Through,
any error stops operations even though
Continuation is selected.
If errors (empty-feed, double-feed, ) oc-
cur for the last set in collation when the
count display method is set to "count-
down method", the machine will stop
when count is 1 even though "Continua-
tion" is selected.