System information

90''
92''
90''
92''
Unit Specifications
6
Cabinet Configurations (90-Minute Runtime)
46''
30''
60''60''
92''
Configuration
“A”
Configuration
“B”
Depth
18
5
/8"
Configuration
“C”
Configuration
“D”
Configuration
“E”
KVA/KW Rating 1.0K 2.0K 2.7K 3.7K 4.8K 5.5K 6.6K 8.3K 10.0K 12.5K 15.0K 17.5K
Power Factor Rating .8 lead to .8 lead to .8 lead to .8 lead to .8 lead to .8 lead to .8 lead to .8 lead to .8 lead to .8 lead to .8 lead to .8 lead to
.75 lag .75 lag .75 lag .75 lag .75 lag .75 lag .75 lag .75 lag .75 lag .75 lag .75 lag .75 lag
Input/Output
Voltage Combinations
Available Single Phase
AC Input Voltage/ 120/20A 120/30A 120/40A 120/50A 120/70A 120/70A 120/80A
Input Circuit Breaker 208/15A 208/20A 208/25A 208/30A 208/40A 208/40A 208/50A 208/70A 208/80A 208/100A 208/125A
Rating 240/15A 240/15A 240/20A 240/25A 240/35A 240/35A 240/45A 240/60A 240/70A 240/80A 240/100A
277/15A 277/15A 277/20A 277/25A 277/30A 277/30A 277/40A 277/50A 277/60A 277/70A 277/90A 277/100A
347/15A 347/15A 347/20A 347/20A 347/25A 347/25A 347/30A 347/50A 347/50A 347/60A 347/80A 347/80A
Output Voltage and 120/8.3 120/16.6 120/22.5 120/30.8 120/40.0 120/45.8 120/55.0 120/69.1 120/83.3 120/104.1 120/125 120/146
Maximum Output Current 240/4.2 240/8.3 240/11.3 240/15.4 240/20.0 240/22.9 240/27.5 240/34.6 240/41.7 240/52.1 240/62.5 240/72.9
In Amperes 277/3.6 277/7.2 277/9.7 277/13.4 277/17.3 277/19.9 277/23.8 277/29.9 277/36.1 277/45.1 277/54.2 277/63.2
347/2.9 347/5.8 347/7.8 347/10.7 347/13.4 347/15.9 347/19.0 347/23.9 347/28.8 347/36.0 347/43.2 347/50.4
Standard Charger Size 5 5 5 5 10 10 10 10 10 15 15 15
(amps)
System DC Voltage 96 96 96 96 96 96 96 144 144 144 144 144
Heat Output (BTU/Hr.) 175 350 473 648 840 963 1,155 1,453 1,750 2,188 2,625 3,063
(1) On systems with 120/240VAC output, loading may not exceed 50% of the system's total KVA rating on any 120V leg. Loading beyond 50% on any 120V leg will cause an unsafe
condition and transformer failure will occur. Call our Service Line at 800-848-6439 for alternate load connection configurations.
(2) An external transformer may be required with certain input/output voltage configurations. Consult factory for details.
(3) Input voltage on 17.5KVA model limited to 277 and 347VAC only.
Standard Battery Systems For 90-Minute Runtime
Type S Battery Maintenance-Free Sealed Lead-Calcium 10-Year Design Life Expectancy
System Capacity 1.0K 2.0K 2.7K 3.7K 4.8K 5.5K 6.6K 8.3K 10.0K 12.5K 15.0K 17.5K
System Configuration
A A A A A B B B B B C C
Total Weight (lbs.) * 838 1,116 1,122 1,222 1,492 1,926 2,130 2,475 2,829 2,861 4,121 4,393
Type G Battery Maintenance-Free Sealed Lead-Calcium 20-Year Design Life Expectancy
System Capacity 1.0K 2.0K 2.7K 3.7K 4.8K 5.5K 6.6K 8.3K 10.0K 12.5K 15.0K 17.5K
System Configuration A A A A B B B B B C D D
Total Weight (lbs.) * 1,365 1,384 1,390 1,472 1,684 2,062 2,630 2,679 3,589 3,657 4,885 5,491
Type N Battery Wet-Cell Nickel-Cadmium 25-Year Design Life Expectancy
Systems Capacity 1.0K 2.0K 2.7K 3.7K 4.8K 5.5K 6.6K 8.3K 10.0K 12.5K 15.0K 17.5K
System Configuration B B B B B C C D D E E Consult
Total Weight (lbs.) * 1,075 1,486 1,644 1,894 2,232 2,532 2,812 3,481 3,940 4,720 5,505 Factory
* Approximate system weights
Input VAC: 120, 208, 240, 277, 347
Output VAC: 120, 240, 277, 347, 120/240
(1)
, 120/277
Other voltages available; consult factory
(2)
Input VAC: 208, 240, 277, 347
(3)
Output VAC: 120, 240, 277, 347,
120/240
(1)
, 120/277
Other voltages available; consult factory
(2)