Taking A Unit Out Of Service
If a unit is to be deliberately taken out of service for an extended period, the positive (+) battery lead should be
disconnected from the charger/transfer module and insulated so that the battery will go into storage in a fully charged
condition. See Fig. 3 or Fig. 4.
LAMP
TERMINALS (-)
BATTERY(+)
BATTERY (-)
LAMP
TERMINALS (+)
VOLT METER (-) [-V OPTION ONLY]
VOLT METER (+) [-V OPTION ONLY]
Fig. 3
1300671
Fig. 4
LED DISPLAY
CONNECTOR
PIN 1 - BLACK
LAMPS (—)
BATTERY (—)
TEST SWITCH
BATTERY (+)
LAMPS (+)
1300738
Replacing A Battery
1. De-energize the AC power.
2. Loosen the (2) chassis retaining screws (Fig. 1).
3. Open the unit and disconnect the battery leads.
4. Release battery retaining strap, and swing to the side.
5. Remove the battery.
6. Replace with a new battery (see unit model label for correct part number).
7. Reassemble the unit.
Replacing An Emergency Lamp
1. To remove the lamp assembly from the lamp housing, place a screwdriver into the slot (Fig. 5), and pry
the lamp assembly out.
2. Insert a screwdriver into the lens slot (Fig. 6) and pry the lens from the reflector assembly.
3. Remove the defective bulb (Fig. 7). Insert a new bulb into the reflector by aligning bulb base with socket and
pushing lamp firmly into socket.
4. Reassemble the lamp:
a. align the small “key”, located between the anti-rotation tabs on the reflector assembly, with the
“keyway” adjacent to the ribbed area on the edge of the lens. (Fig. 7).
b. press the lens into the reflector assembly.
5. Rejoin lamp assembly to lamp housing:
a. orient the lamp assembly’s anti-rotation tabs to the top of the lamp housing.
b. set the bottom of the lamp assembly into the housing and dress wires neatly into the housing cavity.
c. insert a screwdriver into the slot (Fig. 5) and lever the lamp assembly into the housing.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should
always be followed including the following.
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. Do not use outdoors.
2. Do not let power supply cords touch hot surfaces.
3. Do not mount near gas or electric heaters.
4. Equipment should be mounted in locations and at heights where it will not readily be subject
to tampering by unauthorized personnel.
5. The use of accessory equipment not authorized by the manufacturer may cause an
unsafe condition.
6. Do not use this equipment for other than its intended purpose.
7. Servicing of this equipment should be performed by qualied service personnel.
8. Test cycling: the Life Safety Code (NFPA 101) requires testing of emergency lighting units
once a month for a minimum of 30 seconds, and once a year for a minimum of 90 minutes.
INSTALLER:
•SEE UNIT LABEL FOR ADDITIONAL MODEL SPECIFICATIONS
•SAVE THESE INSTRUCTIONS FOR USE BY OWNER/OCCUPANT
1300671
1300738
93021606
93021607
93021608
93027736
Fig. 5
93021606
Fig. 6
ANTI-ROTATION
TABS
LENS
REFLECTOR
ASSEMBLY
RIBBED LENS AREA
93021607
Fig. 7
TO REMOVE LAMP, GRASP FIRMLY
AND PULL STRAIGHT UP
93021608
SURFACE WIRING
BREAKOUT
CHASSIS RETAINING
SCREWS
93027736
Fig. 1

Summary of content (2 pages)