Specification
Web: www.dual-lite.com • Tech Support: (866)-313-3909
701 Millennium Blvd. • Greenville, SC 29607 U.S.A.
Copyright © Dual-Lite, a division of Hubbell Lighting, Inc., All Rights Reserved
Specifications subject to change without notice. • Printed in U.S.A.
0603543 03/18
APPLICATION INFORMATION
EVC Series
Architectural LED Combination Exit/Emergency Light
9"
12" 2.55"
EVC
Electronics
Upon failure of normal utility power, a solid-state transfer switch automatically activates the emergency LED lamp-heads and exit LED’s. Upon resumption
of normal utility power, the battery is disconnected from the load and recharged through a micro-controller based 3 stage constant current/constant voltage
charger. The battery is a maintenance-free Lithium Iron Phosphate (LiFePO
4
) type which operates at 6.4 VDC. The EVC series accepts dual-voltage input of
120 or 277VAC at 50 or 60 Hz, or an optional 220-240VAC input at 50 or 60 Hz. A low voltage battery disconnect (LVD) feature protects the battery from severe
damage during prolonged power failures. Manual testing is available at any time using the push-to-test button.
Number of Lamps- 2 High Power LEDs at 1 watt each configured so that if 1 lamp malfunctions, the remaining lamp will continue to provide illumination.
Lamp Color: Cool White
Total Lamp Output: 88 Lumens per LED
System efficacy: 80lm/W
Rated LED lifecycle: greater than 100,000 hrs or 10 years
Standard Features Include:
• External push-to-test switch and AC-on indicator
• Battery re-charge within 24 hours
• AC Lock-out circuit
• Low voltage battery disconnect
• Conduit entry located at the top center
• Microprocessor controlled pulse charger
Optional Spectron Feature:
• Self-diagnostics monitors LED status, LED load transfer circuit, battery
capacity and charger function and displays any fault detection by means
of a flashing code
• Self-Test feature automatically runs a 1 minute test once a month and
an alternating 30 or 60 minute test once every 6 months. Multi-color
LED indicator provides visible fault detection and charging status.
• User initiated 1 or 90-minute system test feature
• 15 minute re-transfer delay
• Automatic unit transfer in brown-out conditions (below 80% of nominal
AC input voltage)
Operating Temperature Range:
Standard: 68˚F to 86˚F (20˚ to 30˚C)
Damp Listed: 50˚F to 104˚F (10˚ to 40˚C)
Weight: 2.0 lbs
SPECIFICATIONS
DIMENSIONS
MAXIMUM POWER CONSUMPTION
AC
Voltage
Hz. Amps. Watts
Power
Factor
EVC
120 60 0.021 1.65 0.65
277 60 0.017 2.42 0.52
Meets Life Safety Code minimum illuminance of 0.1 fc and average illuminance of 1.0 fc. Assumes open space with no obstructions, mounting height
of 7.5', ceiling height of 9' and reflectances of 80/50/20. Photometry files available on the Dual-Lite web site (www.dual-lite.com).
10'
16'
Single Unit Coverage
PW
1 fc Average
Depth (D) Width (W)
16’ 10’
1 fc Minimum
Depth (D) Width (W)
6’ 10’
Overall height with Canopy is 9.8”