11- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the
projector or between projectors must be carried out using a two pair screened ΓΈ 0.5 mm cable and a XLR
5 pins connector. Ensure that the conductors do not touch each other. Do not connect the cable ground to
the XLR chassy.
The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it
to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the
second one.
This way, all the projectors are cascade connected.
NB. If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX address not valid
- DMX reception problem
For Installations where long distance DMX cable connections are needed, we suggest to use a DMX
terminator.
The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor between pin 2 and 3.
The DMX terminator must be plugged into the last unit (DMX out cable connector) of the DMX line.
1
2
3
5
4
OUT
120 ohm
PIN 3
PIN 2
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
5
3
4 2
1
1=GND
2=DATA-
3=DATA+
DMX OUT
LED OUTPUTS
4
5
6
7
9
2
Pin1
8
ANTENNA
WIRELESS
DMX
)
90-260 Vac
50/60 Hz
DMX IN
DMX OUT
LED OUTPUTS
4
5
6
7
9
2
Pin1
8
ANTENNA
WIRELESS
DMX
)
90-260 Vac
50/60 Hz
DMX IN
CONTROLLER
STANDARD DMX 512
DMX OUT
DELTA 8 B