Owner`s manual

PureLink GmbH
24
4-1.6 Baud Rate Setting
User can set baud rate for RS-232 command control.
1. Enter the Baud rate setting command below. Replace the “#”s with the input and
output number(s).
*255@#! ¶
@001: Baud rate at 19200
@002: Baud rate at 38400
@003: Baud rate at 57600
@004: Baud rate at 115200
Example:
Command Codes
Action
*255@001! ¶
Set baud rate at 19200
*255@002! ¶
Set baud rate at 38400
*255@003! ¶
Set baud rate at 57600
*255@004! ¶
Set baud rate at 115200
Network Configuration:
User can check and set network configuration for LAN control.
Examples:
Command Codes
Action
*255NNI000! ¶
Check current Network Information
*255NIP192.168.000.004! ¶
Set IP address at 125.135.199.004
*255NSM255.255.255.000! ¶
Set Subnet Mask at 255.255.255.000
*255NGW192.168.000.001! ¶
Set Gate Way at 192.168.000.001
*255NMA00.00.C2.B0.20.05! ¶
Set Mac Address at 00.00.C2.B0.20.05
*255NPN3000! ¶
Set Port Number at 3000
Connection Checking:
User can check the connection status.
Example:
Command Codes
Action
*255H000! ¶
Check connection status