4-1.3 Connection Status Check
A connection status can be checked to confirm that the switch has been correctly executed
or to confirm correct routing to multiple outputs. The characters and numbers in a status
command tell the system which input or output to check.
1. Enter the Connection status check command below. Replace the “#”s with the input and
output number(s).
*255?I#!¶ or *255?O#! ¶
Examples:
Command Codes
Action
*255?I01! ¶
Check Output connection status on Input 1
*255?O07! ¶
Check Input connection status on Output 7
*255?ALLIO! ¶
Check all Input and Output connection status
4-1.4 Router ID Check
User can confirm the router’s Current ID setting.
● Universal Router ID is 999
Example:
Command Codes
Action
*999I000! ¶
Check Router’s ID
4-1.5 Firmware Version Check
User can confirm router’s current firmware version.
Example:
Command Codes
Action
*999?version! ¶