Button Operation
To prevent accidental activation, all buttons require at least a 1-second depression.
The Panic-OFF function requires a 3-second press.
The TRANSMIT, RECORD and PANIC buttons toggle their respective functions ON and
OFF.
If the unit is OFF, it automatically powers ON when the any of the three buttons are
pressed.
PANIC (Alarm icon) - This enables/disables a 1kHz pulsed audio tone on the Radio
transmission, and facilitates silent signaling to those monitoring the radio transmission.
RECORD (Unlock icon) - This activates/deactivates the integrated Audio recorder
TRANSMIT (Lock icon) - This activates/deactivates the radio transmitter
The unit is switched OFF by depressing the TRANSMIT and RECORD buttons
simultaneously. You may also turn-OFF each individual function by pressing the
appropriate button.
Status Indication - The unit has no visible indicators to prevent compromise of the
unit’s covert nature during operations. It contains a small Vibrating Motor that provides
momentary feedback when buttons are depressed to confirm the operating mode
(TRANSMIT ONLY, RECORD ONLY, TRANSMIT & RECORD), or OFF. See page 5.
NOTE: If the unit is transmitting, pressing a button will cause the transmission to
cease during the vibration feedback response period. Transmission is immediately
restored thereafter. Recording is not similarly affected.
OPERATION
Panic ON/OFF
Button
Record ON/OFF
Button
Transmit ON/
OFF Button