User Manual
5
QUICK START
The following Quick Start procedure assumes the T-2765-KF has already been configured
via USB as desired. Factory-set transmit frequency and/or other parameter settings can be
modified as described in the Programming section, starting on page 11.
Install the battery by removing the End-Cap using the screwdriver provided, and inserting
the battery, with anode (battery button) head first (unit is protected against accidental
insertion the wrong way round). Re-attach the End-Cap. Note that the unit does
not
power up
automatically.
A Vibrator Motor gives momentary feedback of operating status when buttons are depressed.
Functionality is controlled by the buttons to be in one of five modes:
Mode Initiating Button(s) Tactile Feedback
RECORD: Unlock 1 pulse
TRANSMIT: Lock 2 pulses
TRANSMIT & RECORD Lock then/or Unlock* 3 pulses
PANIC Panic 4 pulses
(SWITCHING) OFF: Lock AND Unlock Vibration switches on
then slowly dies away.
Whenever one of the above modes is toggled off, the resulting mode is whatever is indicated
by the Vibration feedback.
*If RECORD is activated when TRANSMIT is already active, or vice versa, the unit enters
TRANSMIT & RECORD state.
The T-2765-KF is designed to operate in the 150 - 174 MHz frequency band.
USB Connector - Battery
Panic ON/OFF
Button
Record ON/OFF
Button
Transmit ON/
OFF Button
Battery
Compartment
End Cap