Operating Instructions and Installation Instructions
66
6. Specifications
For tone and ringing specifications please see the Country Specific Specification sheet
packaged with this manual.
Electrical Specifications
AC Input to Power Supply 220-240VAC 50 Hz
Power Consumption 20VA (Maximum), 10VA (Idle)
Power Supply Fuse Rating 125 mA, 250V
External Music Port (MOH)
600Ω, 0 dBm / 775mV
Contact Rating (Door Latch) 1A, 24V AC/DC
Ringing Current 70V rms, 50Hz or
70V rms, 25Hz with 25Hz ringer card
External Paging Port
600Ω, 0 dBm/775mV
Real time clock operation during power fail Min. 6 hours
Environmental
Operating Temperature
0-50°C 32-122°F
Optimum Operating Temperature
20-25°C 68-77°F
Storage Temperature
0-70°C 32-158°F
Relative Humidity non-condensing 10%-95%
Loop Limits
These are recommended maximum limits.
Single Line Extensions (900Ω)
3285m Cable 0.4mm
Executive / Standard Terminals / Door phone (mains
power)
950 m Cable 0.4mm
Executive / Standard Terminals / Door phone
(Battery Back-up)
200 m Cable 0.4mm
V24/RS-232C (SMDR Port) 15m Cable 0.4mm
Dialling Specifications
DTMF Dialling
Frequency Deviation Less than +/- 1.5%
Rise time 3 ms.
Section