Owner`s manual
ANTI-MODE 2.0 DUALCORE
OWNER'S MANUAL
You can store up to eight custom measurements (two per sound profile). The
frequency range can be the same as it is on before/after responses. However,
sometimes it can be useful to measure the entire audio band instead. For example, a
full-range measurement may be helpful when trying to find the optimal locations for
acoustical treatments or when finding the perfect toe-in angle for the loudspeakers.
Note that “Measurements” is not the same as “Calibration”. The Measurement tool
simply makes measurements without applying any correction.
To make a custom measurement, navigate to the Room Response (Measurements) in
the Main menu.
➢ Highlight “Make New” and press the OK button.
➢ In the next menu, you can define the range of the measurement: bass (16Hz –
200Hz), bass-midrange (16-500Hz) or full-range (20Hz - 20000Hz). You can also
select the target channel (left, right or both) to be measured.
➢ Remember to check that the microphone is connected. Once you are ready, you can
start the measurement.
With full-range measurements, the alignment of the microphone is more sensitive than
with the bass-only measurements. The microphone should be pointing towards the
ceiling.
➢ Once the first measurement is ready, a secondary measurement slot becomes
available in the Measurements menu. This measurement has the same range as the
first one, but you can select the channel(s) to measure. This enables you to, for
example, compare a room response of the left channel to that of the right channel,
compare the effects of the designed custom filters, different points within the
listening zone and so on.
➢ By pressing LEFT/RIGHT arrow button you can activate a tracker cursor to view the
exact frequency and magnitude value. Pressing UP/DOWN will move the cursor with
a smaller step. (The frequency tracker feature is currently available for bass
measurements only.)
➢ Close the measurement dialog with the OK button to store the measurement.
➢ Remember that each sound profile has its own measurement data. This way, with
up to four profiles available, you can store a maximum of 8 custom measurements.
This is in addition to the 4 ”before / after” responses of the Anti-Mode calibration
measurements that are automatically generated.
Rev. 1.1 2014-03-07 Page 27 (32)