User manual

66
Programs
TPS400-5.0.1en
Warnings / Messages
Important messages Meaning
Selected point has no valid data !
This message occurs if the selected target point has no easting or northing
coordinate.
Max 5 points supported !
If 5 points have already been measured and another point is selected. The
system supports a maximum of 5 points.
Invalid data - no position computed !
The measurements may not allow final station coordinates (Eastings, North-
ings) to be computed.
Invalid data - no height computed !
Either the target height are invalid or insufficient measurements are available
to compute a final station height.
Insufficient space in job ! The present selected job is full and does not allow further storage.
Hz (I - II) > 0.9 deg, measure point again !
This error occurs if a point was measured in one face and the measurement
in the other face differs by more than 180° ±0.9° for the horizontal angle.
V (I - II) > 0.9 deg, measure point again !
This error occurs if a point was measured in one face and the measurement in
the other face differs by more than 360° - V ±0.9° for the vertical angle.
More points or distance required !
There is insufficient data measured to be able to compute a position. Either
there are not enough points used or not enough distances measured.