User manual
63
Programs
TPS400-5.0.1en
[AddPt] Input another backsight point.
[COMPUTE] Calculates and displays the station
coordinates, if at least 2 points and
a distance were measured.
3/I Indicates that the third point in tele-
scope position I was measured.
3/I II Indicates that the third point in tele-
scope positions I and II.
Results
Displays calculated station coordinates:
[PREV] Switches to measurement display,
to measure additional points.
[RESID] Displays residuals.
[StdDev] Displays standard deviation.
[OK] Sets the displayed coordinates and
instrument height as new station.
PREV RESID StdDev OK
STATION COORDINATES
Station : 100
hi : 1.500
EO : 100.506
NO : 100.040
HO : 99.999