Setup step-by-step
1. Extend the tripod legs to allow for a comfortable
working posture. Position the tripod over the
marked ground point, centring it as well as
possible.
2. Fasten the tribrach and instrument onto the
tripod.
3. Turn on the instrument and switch on the laser
plummet and electronic level by pressing [FNC]
> [Level/Plummet].
4. Move the tripod legs (1) and use the tribrach
footscrews (6) to centre the plummet (4) over
the ground point.
5. Adjust the tripod legs to level the circular level
(7).
6. By using the electronic level turn the tribrach
footscrews (6) to precisely level the instrument.
)
Refer to "Levelling up with the electronic
level step-by-step" for more information.
7. Centre the instrument precisely over the ground
point (4) by shifting the tribrach on the tripod
plate (2).
8. Repeat steps 6. and 7. until the required accu-
racy is achieved.