User manual

148
Technical Data
TPS400-5.0.1en
** Standard deviation acc. to ISO 17123-4, beam
interruptions, severe heat shimmer and moving
objects within the beam path can result in deviations
of the specified accuracy.
*** Accuracy and measure time depend on atmo-
spheric conditions, target object and observation
situation.
Distance measurement RL-prism (with reflector)
Range of measurement: .......... from 1000m up
Display unambiguous: ....................... to 12 km
1) Strong haze, visibility 5km; or strong sunlight,
severe heat shimmer
2) Light haze, visibility about 20km; or moderate
sunlight, slight heat shimmer
3) Overcast, no haze, visibility about 40km; no
heat shimmer
EDM
measuring
program
Accuracy Time per
measurement
Standard**
0 - 500 m 2 mm + 2 ppm
typ. 3 - 6 s
max. 12 s
> 500 m 4 mm + 2 ppm
Tracking*** 5 mm + 3 ppm typ. 0.25 s
Ultra & Power: Range (with reflector)
Atmospheric
conditions
Standard-
prism
Reflector tape
60 x 60
1 2200 m (7200 ft) 600 m (2000 ft)
2 7500 m (24600 ft) 1000 m (3300 ft)
3 > 10000 m (33000 ft) 1300 m (4200 ft)