User manual

146
Technical Data
TPS400-5.0.1en
Distance measurement (IR: Reflector mode)
EDM type ..............................................coaxial
Display (least count) ............................... 1 mm
* Beam interruptions, severe heat shimmer and
moving objects within the beam path can result in
deviations of the specified accuracy.
1) Strong haze, visibility 5km; or strong sunlight, severe
heat shimmer
2) Light haze, visibility about 20km; or moderate sunlight,
slight heat shimmer
3) Overcast, no haze, visibility about 40km; no heat
shimmer
Principle: Phase measurement
Type: Coaxial, visible red laser
Class 1
Carrier wave: 658 nm
Measuring system: System analyser basis
100 MHz - 150 MHz
EDM
measuring
program
Accuracy*
(Standard deviation
acc. to ISO 17123-4)
Time per
measure-
ment
IR_Fine
2 mm + 2 ppm typ. 2.4 s
IR_Fast
5 mm + 2 ppm typ. 0.8 s
Tracking
5 mm + 2 ppm typ. < 0.15 s
IR Tape
5 mm + 2 ppm typ. 2.4 s
Range: (normal and rapid measurement)
Standard
prism
3 prisms
(GPH3)
360°
reflector
Tape
60mm x
60mm
Mini
prism
360° Mini
prism
1
1800 m
(6000 ft)
2300 m
(7500 ft)
800 m
(2600 ft)
150 m
(500 ft)
800 m
(2600 ft)
450 m
(1500 ft)
2
3000 m
(10000 ft)
4500 m
(14700 ft)
1500 m
(5000 ft)
250 m
(800 ft)
1200 m
(4000 ft)
800 m
(2600 ft)
3
3500 m
(12000 ft)
5400 m
(17700 ft)
2000 m
(7000 ft)
250 m
(800 ft)
2000 m
(7000 ft)
1000 m
(3500 ft)