Technical information
0-42 [Auto on] Key on LCP
Option: Function:
[0] Disabled No function
[1] * Enabled [Auto on] Key is enabled
[2] Password Avoid unauthorized start in Auto
mode. If 0-42 [Auto on] Key on LCP is
included in the My Personal Menu,
then define the password in
0-65 Personal Menu Password.
Otherwise define the password in
0-60 Main Menu Password.
[3] Enabled without
OFF
[4] Password without
OFF
[5] Enabled with OFF
[6] Password with OFF
0-43 [Reset] Key on LCP
Option: Function:
[0] Disabled No function
[1] * Enabled [Reset] Key is enabled
[2] Password
Avoid unauthorized resetting. If
0-43 [Reset] Key on LCP is included in
the 0-25 My Personal Menu, then
define the password in 0-65 Personal
Menu Password. Otherwise define the
password in 0-60 Main Menu
Password.
[3] Enabled without
OFF
[4] Password without
OFF
[5] Enabled with OFF
[6] Password with OFF
3.2.6 0-5* Copy / Save
Copy parameter settings between set-ups and to/from the
LCP.
0-50 LCP Copy
Option: Function:
[0] * No copy No function
[1] All to LCP Copies all parameters in all set-ups from the
frequency converter memory to the LCP
memory. For service purposes it is
recommended to copy all parameters to the
LCP after commissioning.
[2] All from
LCP
Copies all parameters in all set-ups from the
LCP memory to the frequency converter
memory.
0-50 LCP Copy
Option: Function:
[3] Size indep.
from LCP
Copies only the parameters that are
independent of the motor size. The latter
selection can be used to programme several
frequency converters with the same function
without disturbing motor data which are
already set.
This parameter cannot be adjusted while the motor is
running.
0-51 Set-up Copy
Option: Function:
[0] * No copy No function
[1] Copy to set-
up 1
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 1.
[2] Copy to set-
up 2
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 2.
[3] Copy to set-
up 3
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 3.
[4] Copy to set-
up 4
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 4.
[9] Copy to all Copies the parameters in the present set-up
over to each of the set-ups 1 to 4.
3.2.7 0-6* Password
0-60 Main Menu Password
Range: Function:
100 * [0 - 999 ] Define the password for access to the Main
Menu via the [Main Menu] key. If 0-61 Access
to Main Menu w/o Password is set to Full
access [0], this parameter will be ignored.
0-61 Access to Main Menu w/o Password
Option: Function:
[0] * Full access
Disables password defined in 0-60 Main Menu
Password.
[1] Read only Prevent unauthorized editing of Main Menu
parameters.
[2] No access Prevent unauthorized viewing and editing of
Main Menu parameters.
If Full access [0] is selected then 0-60 Main Menu Password,
0-65 Personal Menu Password and 0-66 Access to Personal
Menu w/o Password will be ignored.
Parameter Description
VLT
®
HVAC Drive Programming Guide
32 MG11CD02 - VLT
®
is a registered Danfoss trademark