0-32 Custom Readout Max Value
Range: Function:
100.00 Custom-
ReadoutUnit*
[ par. 0-31 -
999999.99
CustomRea-
doutUnit]
This parameter sets the max
value to be shown when
the speed of the motor has
reached the set value for
4-13 Motor Speed High Limit
[RPM] or 4-14 Motor Speed
High Limit [Hz] (depends on
setting in 0-02 Motor Speed
Unit).
0-37 Display Text 1
Range: Function:
0 * [0 -
0 ]
In this parameter it is possible to write an individual
text string for display in the LCP or to be read via
serial communication. If to be displayed permanently
select Display Text 1 in 0-20 Display Line 1.1 Small,
0-21 Display Line 1.2 Small, 0-22 Display Line 1.3 Small,
0-23 Display Line 2 Large or 0-24 Display Line 3 Large.
Use the [
▲
] or [
▼
] buttons on the LCP to change a
character. Use the [
◀
] and [
▶
] buttons to move the
cursor. When a character is highlighted by the cursor,
it can be changed. Use the [
▲
] or [
▼
] buttons on the
LCP to change a character. A character can be
inserted by placing the cursor between two
characters and pressing [
▲
] or [
▼
].
0-38 Display Text 2
Range: Function:
0 * [0 -
0 ]
In this parameter it is possible to write an individual
text string for display in the LCP or to be read via
serial communication. If to be displayed permanently
select Display Text 2 in 0-20 Display Line 1.1 Small,
0-21 Display Line 1.2 Small, 0-22 Display Line 1.3 Small,
0-23 Display Line 2 Large or 0-24 Display Line 3 Large.
Use the [
▲
] or [
▼
] buttons on the LCP to change a
character. Use the [
◀
] and [
▶
] buttons to move the
cursor. When a character is highlighted by the cursor,
this character can be changed. A character can be
inserted by placing the cursor between two
characters and pressing [
▲
] or [
▼
].
0-39 Display Text 3
Range: Function:
0 * [0 -
0 ]
In this parameter it is possible to write an individual
text string for display in the LCP or to be read via
serial communication. If to be displayed permanently
select Display Text 3 in 0-20 Display Line 1.1 Small,
0-21 Display Line 1.2 Small, 0-22 Display Line 1.3 Small,
0-23 Display Line 2 Large or 0-24 Display Line 3 Large.
Use the [
▲
] or [
▼
] buttons on the LCP to change a
character. Use the [
◀
] and [
▶
] buttons to move the
cursor. When a character is highlighted by the cursor,
this character can be changed. A character can be
0-39 Display Text 3
Range: Function:
inserted by placing the cursor between two
characters and pressing [
▲
] or [
▼
].
3.2.5 0-4* LCP Keypad
Enable, disable and password protect individual keys on
the LCP.
0-40 [Hand on] Key on LCP
Option: Function:
[0] Disabled No function
[1] * Enabled [Hand on] Key enabled
[2] Password Avoid unauthorized start in Hand
mode. If 0-40 [Hand on] Key on LCPis
included in the My Personal Menu,
then define the password in
0-65 Personal Menu Password.
Otherwise define the password in
0-60 Main Menu Password.
[3] Enabled without
OFF
[4] Password without
OFF
[5] Enabled with OFF
[6] Password with OFF
0-41 [Off] Key on LCP
Option: Function:
[0] Disabled No function
[1] * Enabled [Off] Key is enabled
[2] Password
Avoid unauthorized stop. If 0-41 [Off]
Key on LCP is included in the My
Personal Menu, then define the
password in 0-65 Personal Menu
Password. Otherwise define the
password in 0-60 Main Menu
Password.
[3] Enabled without
OFF
[4] Password without
OFF
[5] Enabled with OFF
[6] Password with OFF