Technical information

Parameter [Units]
0-01 Language
1-20 Motor Power [kW]
[kW]
1-21 Motor Power [HP]
[HP]
1-22 Motor Voltage*
[V]
1-23 Motor Frequency
[Hz]
1-24 Motor Current
[A]
1-25 Motor Nominal Speed
[RPM]
1-28 Motor Rotation Check
[Hz]
3-41 Ramp 1 Ramp Up Time
[s]
3-42 Ramp 1 Ramp Down Time
[s]
4-11 Motor Speed Low Limit [RPM]
[RPM]
4-12 Motor Speed Low Limit [Hz]*
[Hz]
4-13 Motor Speed High Limit [RPM]
[RPM]
4-14 Motor Speed High Limit [Hz]*
[Hz]
3-19 Jog Speed [RPM]
[RPM]
3-11 Jog Speed [Hz]*
[Hz]
5-12 Terminal 27 Digital Input
5-40 Function Relay**
Table 2.1 Quick Setup parameters
*The display showing depends on choices made in 0-02 Motor Speed
Unit and 0-03 Regional Settings. The default settings of 0-02 Motor
Speed Unit and 0-03 Regional Settings depend on which region of
the world the frequency converter is supplied to but can be re-
programmed as required.
** 5-40 Function Relay, is an array, where one may choose between
Relay1 [0] or Relay2 [1]. Standard setting is Relay1 [0] with the
default choice Alarm [9].
See the parameter description in the section Commonly Used
Parameters.
For a detailed information about settings and
programming, please see the VLT
®
HVAC Drive
Programming Guide, MG.11.CX.YY
x=version number
y=language
NOTE
If [No Operation] is selected in 5-12 Terminal 27 Digital
Input, no connection to +24V on terminal 27 is necessary
to enable start.
If [Coast Inverse] (factory default value) is selected in
5-12 Terminal 27 Digital Input, a connection to +24V is
necessary to enable start.
2.1.6 Function Set-ups
The Function set-up provides quick and easy access to all
parameters required for the majority of VLT
®
HVAC Drive
applications including most VAV and CAV supply and
return fans, cooling tower fans, Primary, Secondary and
Condenser Water Pumps and other pump, fan and
compressor applications.
How to access Function set-up - example
Step 1: Turn on the frequency converter (yellow LED lights)
28.8%
14.4Hz
Auto Remote Running
5.66A
2.63kW
0kWh
1 (1)
130BT110.11
Status
Step 2: Press the [Quick Menus] button (Quick Menus
choices appear).
130BT111.10
Q1 My Personal Menu
Q2 Quick Setup
Q3 Function Setups
Q5 Changes Made
13.7% 13.0A 1(1)
Quick Menus
Step 3: Use the up/down navigation keys to scroll down to
Function set-ups. Press [OK].
130BT112.10
Q1 My Personal Menu
Q2 Quick Setup
Q3 Function Setups
Q5 Changes Made
69.3% 5.20A 1(1)
Quick Menus
Step 4: Function set-ups choices appear. Choose Q3-1
General Settings. Press [OK].
Q3
130BT113.10
Q3-1 General Settings
Q3-2 Open Loop Settings
Q3-3 Closed Loop Settings
Q3-4 Application Settings
28.4% 2.05A 1(1)
Function Setups
Step 5: Use the up/down navigation keys to scroll down to
i.e. Q3-11 Analog Outputs. Press [OK].
130BT114.10
26.0%
Q3 - 10 Adv. Motor Settings
Q3 - 11 Analog Output
Q3 - 12 Clock Settings
Q3 - 13 Display Settings
7.14A 1(1)
Q3-1
General Settings
How to Programme
VLT
®
HVAC Drive Programming Guide