Instruction manual
5
Arming The System
Arming the System
1. Access the security system using the steps described in the 'Accessing Your Security System' section of this
manual.
2. Select a partition to arm as described in the 'Accessing Partitions' section of this manual.
If the selected partition is ready to be armed, the system will announce:
'To Turn {Partition X} on Enter Your Access code'
3. Enter your [Access Code]. The system will announce
'Turning {Partition X} on. Exit Delay in Progress.
To turn {Partition X} off, enter your Access Code'
4. If the selected partition is not ready to be armed, the system will announce
'{Partition X} is open. {open zones}.
Secure {Partition X} before turning on.'
When the 'Secure system before turning on' message is heard, ensure that all zones on the partition are secure
(close all doors and windows, stop motion in areas covered by motion detectors) before trying to arm the
partition.
Stay Arming
Stay Arming allows you to arm the system and remain on the premises. Stay arming also cancels the entry delay
on the entry/exit doors. If the entry/exit door is opened, an alarm will sound immediately.
To Stay arm partitions:
1. When the system announces
'To Turn {Partition X} on Enter Your Access code'
press [*]. The system will announce
'To turn {Partition X} on without entry delay press [9]'
2. Press [9]. The system will announce
'Enter Your Access Code'
3. Enter your [Access Code]. The system will announce
'Turning {Partition X} on. Exit Delay in progress'
The selected partition is now armed in the stay mode. Opening the entry/exit door will now sound an immediate
alarm.
S e c t i o n 5