Installation guide
PowerSeries - PC1616/PC1808/PC1832/PC1864
32
[017] Fifth System Options
[018] Sixth System Options
[019] Seventh System Options 
Keypad Zone Assignments
[020] Keypad Zone Assignments
  Only one keypad may be assigned to a zone.
Default 
00
I________I_______I  Keypad (slot 1) Zone 
00
I________I_______I  Keypad (slot 2) Zone 
00
I________I_______I  Keypad (slot 3) Zone 
00
I________I_______I  Keypad (slot 4) Zone 
00
I________I_______I  Keypad (slot 5) Zone 
00
I________I_______I  Keypad (slot 6) Zone 
00
I________I_______I  Keypad (slot 7) Zone 
00
I________I_______I  Keypad (slot 8) Zone 
Opt Def ON OFF
1
9
R
WLS Key Does NOT use Access Codes
R
WLS Key Uses Access Codes
2
9
R
RF Jam Log after 5 Minutes
R
RF Jam Log after 30 Seconds
3
R
Audible RF Jam Trouble Beeps
9
R
Silent RF Jam Trouble Beeps
4
R
Double Hit Enabled
9
R
Double Hit Disabled
5
R
Late to Close Enabled
9
R
Late to Close Disabled
6
R
Daylight Savings Time Enabled
9
R
Daylight Savings Time Disabled
7
R
For Future Use
9
R
8
R
Squawk on Away Key Arming/Disarming Only
9
R
Squawk on all Arming/Disarming
Opt Def ON OFF
1
R
Test Transmission Exception Enabled
9
R
Test Transmission Exception Disabled
2
R
For Future Use
9
R
3
R
For Future Use
9
R
4
R
For Future Use
9
R
5
9
R
Keypad Buzzer Follows Bell Enabled
R
Keypad Buzzer Follows Bell Disabled
6
R
Cross Zoning Enabled
9
R
Police Code Enabled
7
R
Exit Delay Restart Enabled 
9
R
Exit Delay Restart Disabled
8
R
AC Trouble Beeps Enabled
9
R
AC Trouble Beeps Disabled
Opt Def ON OFF
1
R
For Future Use 
9
R
2
R
Troubles are Latching
9
R
Troubles follow restore
3
R
First Zone in Alarm Enabled 
9
R
First Zone in Alarm Disabled
4
R
For Future Use 
9
R
5
R
For Future Use 
9
R
6
R
Green Keypad LED Power Indication
9
R
Ready Indication
7
R
 [4][6] Accessable by All Users
9
R
Master Code Only
8
R
For Future Use 
9
R
 Only one keypad may be 
assigned to a slot. Only one 
zone can be assigned to a 
keypad. Valid entries are 
from 01 to 64.