Installation manual

Programming Worksheets
29
Keypad Programming
[000] Keypad Enrollment (Section 2.5 “Keypad Assignment” on page 4)
NOTE: This must be done at each keypad requiring programming.
[0] Slot [Valid entries are 11-18; i.e. enter [11] for slot 1, [12] for slot 2, etc.]
[1] Function Key 1 Assignment (Valid entries are 00-17)
[2] Function Key 2 Assignment (Valid entries are 00-17)
[3] Function Key 3 Assignment (Valid entries are 00-17)
[4] Function Key 4 Assignment (Valid entries are 00-17)
[5] Function Key 5 Assignment (Valid entries are 00-17)
Function Key Options:
Slot Function Function Function Function Function
Key 1 Key 2 Key 3 Key 4 Key 5
LED Defaults 11 03 04 06 14 16
LCD Defaults 18 03 04 06 14 16
KEYPAD 1
I________I________I I________I I________I I________I I________I I________I
KEYPAD 2 I________I________I I________I I________I I________I I________I I________I
KEYPAD 3 I________I________I I________I I________I I________I I________I I________I
KEYPAD 4 I________I________I I________I I________I I________I I________I I________I
KEYPAD 5 I________I________I I________I I________I I________I I________I I________I
KEYPAD 6 I________I________I I________I I________I I________I I________I I________I
KEYPAD 7 I________I________I I________I I________I I________I I________I I________I
KEYPAD 8 I________I________I I________I I________I I________I I________I I________I
Basic Programming
Zone Definitions
NOTE:Keypads must be installed to use 24-hour Buzzer zones.
NOTE:Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is in
sections [202] - [205].
[001] Zone 1-8 Definitions (Section 5.2 “Zone Programming” on page 15)
Default Default
01 I_______I_______I Zone 1 00 I_______I_______I Zone 5
03
I_______I_______I Zone 2 00 I_______I_______I Zone 6
04
I_______I_______I Zone 3 00 I_______I_______I Zone 7
04
I_______I_______I Zone 4 00 I_______I_______I Zone 8
00 Null Key 08 [*][1] Bypass Mode 16 [*][0] Quick Exit
01 For future use 09 [*][2] Trouble Display 17 [*][1] Reactivate Stay/Away’s
02 For future use 10 [*][3] Alarm Memory 18 For future use
03 Stay Arm 11 [*][5] User Programming 19 For future use
04 Away Arm 12 [*][6] User Functions 20 For future use
05 [*][9] No-Entry Arm 13 Command Output #1 [*][7][1] 21 For future use
06 [*][4] Chime On / Off 14 Command Output #2 [*][7][2]
07 [*][6][——][4] System Test 15 For future use
00 Null Zone (Not Used) 10 24 Hour Supervisory Buzzer 20 24 Hour Freeze
01 Delay 1 11 24 Hour Burglary 21 24 Hour Latching Tamper
02 Delay 2 12 24 Hour Holdup 22 Momentary Keyswitch Arm
03 Instant 13 24 Hour Gas 23 Maintained Keyswitch Arm
04 Interior 14 24 Hour Heating 24 LINKS Answer
05 Interior, Stay/Away 15 24 Hour Medical 25 Interior Delay
06 Delay, Stay/Away 16 24 Hour Panic 87 Delay 24 Hour Fire (Wireless)
07 Delayed 24 Hour Fire (Hardwired) 17 24 Hour Emergency 88 Standard 24 Hour Fire (Wireless)
08 Standard 24 Hour Fire (Hardwired) 18 24 Hour Sprinkler
09 24 Hour Supervisory 19 24 Hour Water