Installation manual
26
(Downloading Telephone Number) . . . . . . . . . . Section [490]
Communicator Call Direction Options. . . Section [361]-[368]
Call LINKS as well as Land Line . . . . . . . . .Section [380]: [7]
LINKS Special Preamble. . . . . . . . . . . . . . . . . . Section [393]
5.27 Additional System Modules
The following modules are programmed through the module
programming sections [801]-[804]: the PC5400 Printer/
DVACS module, the Links2X50 Long-Range Radio module,
the Skyroute transceiver module, and the PC5132 Wireless
Receiver and all of its devices. For instructions on the installa-
tion and programming of these additional modules and
devices, please see their respective installation and program-
ming manuals.
PC5400 Printer Module Programming. . . . . . . . Section [801]
Alternative Comm. (LINKS2X50, Skyroute, PC5400DVACS)
Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . Section [803]
PC5132 Programming. . . . . . . . . . . . . . . . . . . . Section [804]
5.28 Resetting Factory Defaults
On occasion, it may be necessary to default the main control
panel or one of the connected modules: the LINKS2X50 Radio
interface, Skyroute module, the PC5132 wireless receiver, and
the PC5400 Printer/DVACS module.
To default the main control panel (hardware), perform the fol-
lowing:
1. Remove AC and battery from the panel.
2. Remove all wires from the Zone 1 and PGM1 terminals.
3. With a piece of wire short the Zone 1 terminal to the PGM1
terminal.
4. Apply AC power to the main panel.
5. When Zone Light 1 is lit on the keypad the default is com-
plete.
6. Remove AC power from the control
7. Reconnect all original wiring and power up the control.
NOTE: AC power must be used to power the panel. The panel
will not default if only the battery is used.
To default the main control panel software and other modules,
perform the following:
1. Enter the Installer’s Programming mode.
2. Enter the appropriate programming section [XXX].
3. Enter the Installer’s Code.
4. Re-enter the appropriate programming section [XXX].
The panel will take a few seconds to perform the default.
When the keypad is again operational the default is complete.
NOTE:If using Identified Wireless Keys (PC5132 v3.0 or later
only), when the main panel is defaulted, all wireless key
access codes must be re-programmed. Refer to your PC5132
v3.0 Installation Manual for more information.
Restore Alternative Communicator
(LINKS2X50, Skyroute, PC5400DVACS)
to Default Programming. . . . . . . . . . . . . . . . . . . Section [993]
Restore PC5132 to Default Programming . . . . . Section [996]
Restore PC5400 Printer to Default ProgrammingSection [997]
Restore Panel to Default Programming . . . . . . . Section [999]
5.29 Installer’s Lockout
If Installer’s Lockout is selected, a hardware default cannot
be performed. If a software default is performed, all program-
ming will restore to factory default.
If Installer’s Lockout Disable is selected, the panel will
restore all programming to factory defaults when a hardware
or software default is performed on the main control panel.
To enable or disable Installer’s Lockout, perform the following:
1. Enter the Installer’s Programming mode.
2. Enter the appropriate programming section: [990] or [991].
3. Enter the Installer’s Code.
4. Re-enter the appropriate programming section: [990] or
[991].
Installer Lockout Enable . . . . . . . . . . . . . . . . . . Section [990]
Installer Lockout Disable . . . . . . . . . . . . . . . . . Section [991]
5.30 Walk Test (Installer)
The Installer Walk Test can be used to test the alarm state of
each zone of the panel. The walk test cannot be used to test
zone type [24].
Before beginning the walk test, ensure the following condi-
tions are met:
1. The panel is disarmed
2. The Keypad Blanking option is disabled (section [016]:
[3])
3. The Fire Bell is Continuous option is disabled (section
[014]: [8])
4. The Transmission Delay is disabled, if Transmission
Delay is not required (section [370])
NOTE: Fire Troubles are not supported in Walk Test.
To perform a walk test:
Step 1 - Enter Installer Programming
Step 2 - Enter Section [901]
When any zone is violated the panel will activate the Bell Out-
put for two seconds, log the event to the event buffer and
communicate the alarm to central station.
Test each zone several times. Check the event buffer to
ensure that all zones and FAP keys are functioning properly.
NOTE: Zones with the Force Arm attribute enabled, will not
cause the Ready light to go out when they are violated.
To stop the test:
Step 1 - Enter Installer Programming
Step 2 - Enter section [901]
NOTE:The alarm memory is cleared upon entering Walk Test
mode. When the walk test is complete, the Alarm Memory light
will remain lit, but there will be no alarms in memory. The light
will turn off the next time the panel is armed.
Installer Walk Test Enable/Disable . . . . . . . . . . Section [901]